LCS85 technical specifications - Metasys - LIT-12011832 - General System Information - Metasys System - 12.0

Metasys System Configuration Guide

Product
Building Automation Systems > Building Automation Systems > Metasys System
Document type
Configuration Guide
Document number
LIT-12011832
Version
12.0
Revision date
2024-07-17
Product status
Active
Table 1. LCS85 software system recommendations for installation or upgrade

Recommended computer platform

Intel Xeon E5506, 2.13 GHz, 4 MB Cache

2 x 160 GB 7.2K SATA, 8.9 cm (3.5 in.) Cabled

3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS Controller)

Recommended memory

16 GB RAM minimum; 32 GB RAM recommended

Hard disk

160 GB minimum

Supported operating systems and software

  • Windows® Server® 2019 (version 1809 or later) (64-bit)
  • Windows® Server® 2016 (version 1607 or later) (64-bit)
  • Windows® 10 Pro and Windows 10 Enterprise Editions versions 21H2, 22H2 (64-bit).
Note: Microsoft .NET Framework 3.5 Service Pack (SP) 1 and Microsoft .NET Framework 4.7.2 are required for LCS85 software.

Internal optical drive

DVD ROM, SATA

Supported web browser Software for Metasys Site Management Portal client computers

Microsoft® Edge® version 91 or later

Apple® Safari® 13.1 or later

Supported virtual environments

Microsoft Hyper-V™, VMWare®

Network communication

Selectable Network Interface (if computer has multiple network cards, during LCS85 installation, select the network card that was configured for Metasys system use before installation)

Ethernet network interface card 10/100/1000 Mbps (100 Mbps or better recommended)

Recommended data protection

Uninterruptible power supply (UPS)

Smart-UPS SC 450VA, 280 W, 120 VAC input/output, NEMA 5-15R output connections, OEM Part No. SC450RM1U