The following menus are available in the Security Administrator.
Menu |
Selection |
Description |
---|---|---|
File |
Exit |
Closes the Security Administrator. |
Save |
Saves the modified permissions in the security grid. |
|
Edit |
Delete |
Deletes user-defined role or user-defined user. Prompts for confirmation before deleting. |
Properties |
Opens the Role Properties or User Properties window. |
|
System Access Permissions |
Opens the System Privileges dialog box. |
|
Account Disabled |
Marks the selected user account as disabled. Next time you
attempt to log in to the system, an account disabled message
appears. Your user account must be re-enabled by an
administrator through the User Properties.
Note: This option is
not available to Active Directory service users.
|
|
Insert |
New User |
Adds a new user to the Roles and Users tree. The User Properties dialog box appears. |
New Role 1 |
Adds a new role to the Roles and Users tree. The Role Properties dialog box appears. |
|
Copy of User |
Inserts a copy of the selected user into the Roles and Users tree. The User Properties dialog box appears. You may edit the copied user’s properties. |
|
Copy of Role1 |
Inserts a copy of the selected role into the Roles and Users tree. The Role Properties dialog box appears allowing you to edit the copied roles. |
|
Insert Active Directory User |
Adds a new Active Directory service user to the Roles and Users tree. The User Properties dialog box appears. |
|
Insert RADIUS User |
Adds a new RADIUS user to the Roles and Users tree. The User Properties dialog box appears. |
|
View |
Tool Bar |
Displays the Security Administrator toolbar. |
User Preferences File Names |
Allows the MetasysSysAgent administrator to view the name of the user preferences file for each account. You view file names to manage user and system preferences files on the device. Refer to the ADS/ADX Commissioning Guide (LIT-1201645) , the NAE Commissioning Guide (LIT-1201519) , the ODS Commissioning Guide (LIT-12011944) or the Open Application Server (OAS) Commissioning Guide (LIT-12013243) for details. |
|
Server Configuration |
Active Directory |
Configures Active Directory service for use by Metasys system users. The Configure Active Directory dialog box appears. |
RADIUS |
Configures Remote Authentication Dial-In User Service (RADIUS), which is a networking protocol that provides centralized authentication, authorization, and accounting management for users who connect and use a network service. The RADIUS dialog box appears. |
|
Help |
Help Topics |
Opens the Metasys Site Management Portal Help (LIT-1201793) . There is no Help system for the Security Administrator system. Information on the Security Administrator system is located only in this document. Note: A File Download dialog box may appear.
To open the Help system, click Open.
|
About Metasys |
Opens the About Metasys pop-up box that displays the system name, installed version, version number, graphics version, and copyright stamp. Click Terms & Conditions for terms and conditions of use information. |