When a trouble condition occurs your Alarm System identifies the problem and displays an error message. Refer to the table below when you see an error message on the display. If additional help is required, contact your distributor for service.
When the system detects a trouble condition the following occurs:
- The Trouble indicator turns on.
- The keypad beeps twice every 10 seconds. Press the [*] key to silence the keypad beeps.
Press [*][2] to examine troubles. When viewing troubles, the trouble indicator flashes to identify the level of trouble being viewed. One flash = level 1, two flashes = level 2 etc. Arming of your system may be impeded by a trouble. To override this condition, enter [*][2], scroll to Acknowledge All Troubles and press [*] or enter 999.
| Trouble Condition |
Trouble Level 1 |
Description | Trouble Types | Trouble Level 2 | Notification Level 3 |
|---|---|---|---|---|---|
|
Trouble numbers are used to view the trouble. Trouble Notification identifies the range that may be displayed on the keypad. When exploring the trouble levels, the Trouble indicator will flash to identify which level you are currently viewing. |
|||||
|
Service Required |
01 |
Assorted Trouble types. Time and Date troubles can be resolved by resetting the Time/Date. To set Time/Date press [*][6][0][1]. For all other troubles call for service. |
Bell Circuit |
01 |
|
|
RF Jam |
02 |
||||
|
Loss of clock |
04 |
||||
|
Output 1 Fault |
05 |
||||
|
Warm Start |
|||||
|
USB Wi-Fi Connected |
|||||
|
Component fault in power unit |
|||||
|
Power Fail Bus Repeater |
Repeater 1-16 |
||||
|
Power Fail 3A Supply |
Power Supply 1-4 |
||||
|
Overcurrent |
Call for service |
||||
|
Battery Trouble |
02 |
The system has detected a battery trouble condition. Call for service. |
Low Battery |
01 |
n/a |
|
No Battery |
02 |
n/a |
|||
|
Low Battery High-current O/P |
04 |
Module 1-4 |
|||
|
No Battery High-current O/P |
05 |
Module 1-4 |
|||
|
Low Battery 1A Power Supply |
07 |
Module 1-4 |
|||
|
No Battery 1A Power Supply |
08 |
Power supply 1-4 |
|||
|
Low Battery Bus Repeater |
10 |
Repeater 1-16 |
|||
|
No Battery Bus Repeater |
11 |
Repeater 1-16 |
|||
|
Low Battery 1 3A Power Supply |
13 |
Power Supply 1-4 |
|||
|
Low Battery 2 3A Power Supply |
14 |
Power Supply 1-4 |
|||
|
No Battery 1 3A Power Supply |
15 |
Power Supply 1-4 |
|||
|
No Battery 2 3A Power Supply |
16 |
Power Supply 1-4 |
|||
|
Bus Voltage |
03 |
A module has detected a low voltage on its corbus red terminal. |
HSM2HOST |
01 |
n/a |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Zone Expander |
04 |
Zone expander 1-30 |
|||
|
1A Power Supply |
05 |
Power Module 1-4 |
|||
|
High-current Output |
06 |
Output Module 1-4 |
|||
|
System Area |
07 |
n/a |
|||
|
Output Expander |
08 |
Module 1-16 |
|||
|
Audio Module |
09 |
n/a |
|||
|
8 I/O Module |
10 |
Module 1-30 |
|||
|
Bus Repeater |
11 |
Repeater 1-16 |
|||
|
Bus Fault Bus Repeater |
12 |
Repeater 1-16 |
|||
|
3A Power Supply |
13 |
Power Supply 1-4 |
|||
|
AC Troubles |
04 |
The system is experiencing loss of power. Call for service. If the building and/or neighborhood has lost electrical power, the system will continue to operate on battery for several hours. |
Zone |
01 |
Zone label or 001-248 |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
Power Supply |
05 |
Power supply 1-4 |
|||
|
High-current Output |
06 |
Output terminal 1-4 |
|||
|
System Area |
07 |
n/a |
|||
|
Bus Repeater |
08 |
Repeater 1-16 |
|||
|
3A Power Supply |
09 |
Power Supply 1-4 |
|||
|
Device Faults |
05 |
The system has detected an issue with one or more connected devices. Call for service. |
Zone |
01 |
Zone label or 001-248 |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
Device Mask |
06 |
Zone 001-248 |
|||
|
Gas |
07 |
Zone 001-248 |
|||
|
Heat |
08 |
Zone 001-248 |
|||
|
CO |
09 |
Zone 001-248 |
|||
|
Freeze |
10 |
Zone 001-248 |
|||
|
Probe Disconnected |
11 |
Zone 001-248 |
|||
|
Fire |
12 |
Zone 001-248 |
|||
|
Device Battery |
06 |
The system detected an issue with one or more device batteries. For zone, keypad and wireless key battery troubles see the accompanying documentation for how to change the batteries. |
Zone |
01 |
Zone label or 001-248 |
|
Keypad |
02 |
Keypad 1-16 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
User |
05 |
Wireless key 1-32 |
|||
|
Device Tampers |
07 |
The system has detected a tamper condition with one or more devices on the system. Call for service. |
Zone |
01 |
Zone label or 001-248 |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
Audio Station |
05 |
Station 1-4 |
|||
|
RF Delinquency |
08 |
The system has detected wireless signal interference that is causing improper system operation. Call for service. |
Zones |
01 |
Zone label or 001-248 |
|
Keypad |
02 |
Keypad 1-16 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
Module Supervision |
09 |
The system has detected a supervisory trouble condition with one or more modules on the system. Call for service. |
HSM2HOST |
01 |
n/a |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Zone Expander |
04 |
Expander 1-30 |
|||
|
Power Supply |
05 |
Power Supply 1-4 |
|||
|
High-current Output |
06 |
Output terminal 1-4 |
|||
|
Output Expander |
08 |
Output module 1-16 |
|||
|
Audio Module |
09 |
||||
|
I/O Module |
10 |
Module 1-30 |
|||
|
Bus Repeater |
11 |
Repeater 1-16 |
|||
|
3A Supply |
12 |
Power Supply 1-4 |
|||
|
Module Tampers |
10 |
The system has detected a tamper condition with one or more modules on the system. Call for service. |
HSM2HOST |
01 |
n/a |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Zone Expander |
04 |
Zone Expander 1-30 |
|||
|
Power Supply |
05 |
Power Supply 1-4 |
|||
|
High-current Output |
06 |
Output terminal 1-4 |
|||
|
Output Expander |
08 |
Output module 1-16 |
|||
|
Audio Module |
09 |
n/a |
|||
|
I/O Module |
10 |
Module 1-30 |
|||
|
Bus Repeater |
11 |
Repeater 1-16 |
|||
|
3A Power Supply |
12 |
Power Supply 1-4 |
|||
|
Communications |
11 |
The system has detected a communication trouble. Call for service. |
Telephone line monitoring |
01 |
n/a |
|
Failure to communicate |
02 |
Receiver 1-4 |
|||
|
SIM Lock |
03 |
n/a |
|||
|
Cellular |
04 |
n/a |
|||
|
Ethernet |
05 |
n/a |
|||
|
Receiver |
06 |
Receiver 1-4 |
|||
|
Supervision Receiver |
07 |
Receiver 1-4 |
|||
|
Alt Comm Fault |
09 |
n/a |
|||
|
Alt Comm FTC |
10 |
Receiver 1-4 |
|||
|
Not Networked |
12 |
The system has detected a network trouble condition with one or more modules on the system. If the trouble does not restore within 20 minutes, call for service. |
Zone |
01 |
Zone label 001-248 |
|
Keypad |
02 |
Keypad 1-32 |
|||
|
Siren |
03 |
Siren 1-16 |
|||
|
Repeater |
04 |
Repeater 1-8 |
|||
|
User |
05 |
Users 01-1000 |
|||
|
AUX Trouble |
13 |
The system has detected a trouble on the AUX terminal. |
Zone |
01 |
Zone |
|
Power Supply |
05 |
Power Supply 1-8 |
|||
|
High-current O/P |
06 |
Module 1-4 |
|||
|
System Area |
07 |
n/a |
|||
|
8 I/O Module |
10 |
Module 1-30 |
|||
|
Bus Repeater |
11 |
Repeater 1-8 |
|||
|
3A Power Supply Aux 1 |
12 |
Aux 1 Trouble |
|||
|
3A Power Supply Aux 2 |
13 |
Aux 2 Trouble |
|||
| Limited Exceeded | 14 | The system detects incompatibility with third-party firmware. | Interactive zone limit |
01 |
n/a |
| Interactive partition limit |
02 |
n/a | |||