Before you install the reporting services, see the following table to ensure that your software location is correct for your specific configuration.
Note:
Metasys Advanced Reporting System and Energy
Essentials does not support SQL Server 2019.
Unified configuration | Split configuration | |
---|---|---|
SQL Server database engine software | Host computer | Database computer |
Server software | Host computer | Web or application computer |
- Launch the SQL Server Installation Center program.
- On the left pane, click Installation.
- On the right pane, click the Install SQL Server Reporting Services link.
- On the Microsoft web page, click the SQL Server 2019 Reporting Services link. Download and run the installation file.
- Run the Microsoft SQL Server 2019 Reporting Services executable file.
- On the Welcome page, click Reporting Services. Click Next.
- On the Choose an edition to install page, in the Enter the product key field, type a product key. Click Next.
- On the Review the license terms page, read and click the I accept the license terms check box. Click Next.
- On the Install Database Engine page, select the Install Reporting Services only option. Click Next.
- On the Specify an install location page, select a custom install location, or accept the default and click Install. The progress bar indicates the installation status. Click Next.
- On the Setup completed page, to confirm the installation was successful, select the Configure manually and customize settings option, and click Configure report server. When the Report Server Configuration Manager launches, if the Report Server Connection dialog box does not automatically appear, you do not have SQL Server Reporting Services successfully installed. If it does appear, click Cancel. For information on troubleshooting, see SQL Server Reporting Services troubleshooting
Note: To configure the report server, see Configuring SQL Server Reporting Services.