P499 Series Electronic Pressure Transducers Product/Technical Bulletin

Product
Switches and Electrical > Pressure Transducers > P499 Electronic Pressure Transducer
Document number
LIT-12011190
Document revision
G
Revision date
2019-07-08
Part number
24-7664-2659
Table 1. P499 Series Electronic Pressure Transducers
Pressure ranges
  • -10 psi to 100 psi
  • 0 psi to 100 psi
  • 0 psi to 200 psi
  • 0 psi to 500 psi
  • 0 psi to 750 psi
Maximum working pressure 2x pressure range; short duration; infrequent, abnormal condition
Burst pressure 5x pressure range
Vacuum 30 microns (0.03 mm Hg); short term
Media compatibility All media compatible with 17-4PH stainless steel, including ammonia
Output signal 0.5 VDC to 4.5 VDC, 0 VDC to 10 VDC, or 4 mA to 20 mA
Supply voltage 0.5 VDC to 4.5 VDC ratiometric output 5.0 ±0.25 VDC, Safety Extra-Low Voltage (SELV) or Class 2
4 mA to 20 mA output 9 VDC to 30 VDC, SELV or Class 2
0 VDC to 10 VDC output 12 VDC to 30 VDC, SELV or Class 2
Direct-mount pressure connections 1/8in. -27 NPT External Thread (Style 49),1/4 in. SAE 45° Flare Internal Thread (7/16-20 UNF) with Depressor (Style 47)
Temperature and humidity Storage -40°F to 257°F (-40°C to 125°C)
Operating -40°F to 185°F (-40°C to 85°C)
Compensated range -4°F to 185°F (-20°C to 85°C)
Humidity 0 to 100% RH
Linearity ±0.25% Full Span Best Fit Straight Line
Accuracy ±1% Full Span (maximum) over compensated temperature range
Materials Pressure port 17-4PH stainless steel construction
Packard connector 40% glass-filled Polyetherimide (PEI)
Vibration   20G, 20 to 200 Hz
Shock   200G/11 ms
Compliance United States UL Listed, File E29374, CCN NKPZ

UL Recognized for Use in Class I, Division 2 Hazardous Locations, File E322274

  Canada UL Listed, File E29374, CCN NKPZ7

UL Recognized for Use in Class I, Division 2 Hazardous Locations, File E322274

CE Mark Europe CE Mark – Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC
  Australia/New Zealand C-Tick Mark, Emissions Compliant

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls/PENN Refrigeration Application Engineering at 1-800-275-5676. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products.