What are the available Water Valve symbols?
|
Small Valve 2 Way Electric |
Small Valve 2 Way Pneumatic |
|
Large Valve 2 Way Electric Horizontal |
Large Valve 2 Way Pneumatic Horizontal |
|
Large Valve 2 Way Electric Vertical |
Large Valve 2 Way Pneumatic Vertical |
|
Small Valve 3 Way Electric |
Small Valve 3 Way Pneumatic |
|
Large Valve 3 Way Electric Horizontal |
Large Valve 3 Way Pneumatic Horizontal |
|
Large Valve 3 Way Electric Vertical |
Large Valve 3 Way Pneumatic Vertical |
|
Check Valve Horizontal |
Check Valve Horizontal Type 2 |
|
Check Valve Vertical |
Check Valve Vertical Left |
|
Check Valve Vertical Right |
Hand Valve 2 Way Vertical |
|
Hand Valve 3 Way Horizontal |
Hand Valve 3 Way Vertical |
|
Hand Valve 2 Way Horizontal |
Manual Valve Vertical |
|
Manual Valve Horizontal |
Tap Vertical |
|
Tap Horizontal |
Valve 2 Way Electric Horizontal Left for Air-Side Equipment |
|
Valve 2 Way Electric Horizontal Right for Air-Side Equipment |
Valve 2 Way Electric Vertical for Air-Side Equipment |
|
Valve 3 Way Electric Vertical for Air-Side Equipment |
Valve 3 Way Electric Horizontal Left for Air-Side Equipment |
|
Valve 3 Way Electric Horizontal Right for Air-Side Equipment |
What are the properties available on the Water Valve symbols?
Property Panel
The following Water Valve symbols have an Orientation (Horizontal or Vertical) Property panel property: Small Valve 2 Way Electric, Small Valve 2 Way Pneumatic, Small Valve 3 Way Electric, Small Valve 3 Way Pneumatic,
All other Water Valve symbols have no Property panel properties.
Binding Properties
| Binding | Short Name | Animation Available |
|---|---|---|
| Valve Primary Value | CLG-O | No |
| Valve Secondary Value | N/A | No |
| Navigation | N/A | No |
All other Water Valves not listed here or in this section separately do not have Binding properties.
Snapping Properties
| Symbol | Snaps To |
|---|---|
| Small Valve 2 Way Electric (Horizontal Orientation)
Small Valve 2 Way Pneumatic (Horizontal Orientation) Large Valve 2 Way Electric Horizontal Large Valve 2 Way Pneumatic Horizontal Small Valve 3 Way Electric (Horizontal Orientation) Small Valve 3 Way Pneumatic (Horizontal Orientation) Check Valve Horizontal Hand Valve 2 Way Horizontal Manual Valve Horizontal |
Pipes: Horizontal End, Horizontal, and Horizontal Continuation pipes |
| Small Valve 2 Way Electric (Vertical Orientation)
Large Valve 2 Way Electric Vertical Large Valve 2 Way Pneumatic Vertical Small Valve 3 Way Electric (Vertical Orientation) Small Valve 3 Way Pneumatic (Vertical Orientation) Check Valve Horizontal Type 2 Check Valve Vertical Hand Valve 2 Way Vertical Manual Valve Vertical |
Pipes: Diagonal End, Diagonal, and Diagonal Continuation pipes |
| Small Valve 2 Way Pneumatic (Vertical Orientation) | Pipes: Diagonal Continuation |
| Large Valve 3 Way Electric Horizontal
Large Valve 3 Way Pneumatic Horizontal Large Valve 3 Way Electric Vertical Large Valve 3 Way Pneumatic Vertical |
Pipes: Horizontal, Horizontal End Pipes, Horizontal Continuation Pipe, Diagonal, Diagonal End Diagonal Continuation pipes |
| Check Valve Vertical Left
Check Valve Vertical Right |
Pipes: Vertical and Vertical End pipes |
| Hand Valve 3 Way Vertical
Hand Valve 3 Way Horizontal |
Pipes: Diagonal, Diagonal End, Diagonal Continuation Pipe, Vertical Pipe, and Vertical Continuation pipes |
| Check Valve Horizontal Type 2
Check Valve Vertical Left Check Valve Vertical Right |
Pipes: Air-Side Pipes |
What are the Binding properties available on the Large Valve 2 Way Electric Horizontal and Large Valve 2 Way Electric Vertical symbols?
| Binding | Animation Available |
|---|---|
| Two Way Electric Valve Primary Command | No |
| Two Way Electric Valve Secondary Value | No |
| Navigation | No |
What are the Binding properties available on the Large Valve 2 Way Pneumatic Horizontal and Large Valve 2 Way Pneumatic Vertical symbols?
| Binding | Animation Available |
|---|---|
| Two Way Pneumatic Valve Primary Command | No |
| Two Way Pneumatic Valve Secondary Value | No |
| Navigation | No |
What are the Binding properties available on the Large Valve 3 Way Electric Horizontal and Large Valve 3 Way Electric Vertical symbols?
| Binding | Animation Available |
|---|---|
| Three Way Electric Valve Primary Command | No |
| Three Way Electric Valve Secondary Value | No |
| Navigation | No |
What are the Binding properties available on the Large Valve 3 Way Pneumatic Horizontal and Large Valve 3 Way Pneumatic Vertical symbols?
| Binding | Animation Available |
|---|---|
| Three Way Pneumatic Valve Primary Command | No |
| Three Way Pneumatic Valve Secondary Value | No |
| Navigation | No |