Dimensions - Johnson Controls - LIT-1901223 - DXUB2F150C.111621 - VP3C2P20B.110601 - VP3C2P20B.110621 - VP3C2P20B.111601 - VP3C2P20B.111621 - VP3MB2D020C.111721 - VP3MB2D025C.111721 - VP3MB2D032C.111721 - VP3MB2D040C.111721 - VP3MB2D050C.111721 - VP3N6C15B.120601 - VP3N6C15B.120621 - VP3N6C15B.121601 - VP3N6C15B.121621 - VP3N6P25B.120601 - VP3N6P25B.120621 - VP3N6P25B.121601 - VP3N6P25B.121621 - VP3UB2F065C.111621 - VP3UB2F080C.111621 - VP3UB2F100C.111621 - Pressure independent control valve - Valves and actuators - VP3C2P20B.111601 Electronic Pressure-Independent Control Valve - VP3C2P20B.111621 Electronic Pressure-Independent Control Valve - VP3MB2D015C.111721 Electronic Pressure-Independent Control Valve - VP3MB2D020C.111721 Electronic Pressure-Independent Control Valve - VP3MB2D025C.111721 Electronic Pressure-Independent Control Valve - VP3MB2D032C.111721 Electronic Pressure-Independent Control Valve - VP3MB2D040C.111721 Electronic Pressure-Independent Control Valve - VP3MB2D050C.111721 Electronic Pressure-Independent Control Valve - VP3N6C15B.121001 Electronic Pressure-Independent Control Valve - VP3N6C15B.121601 Electronic Pressure-Independent Control Valve - VP3N6C25B.121001 Electronic Pressure-Independent Control Valve - VP3N6C25B.121601 Electronic Pressure-Independent Control Valve - VP3UB2F065C.111621 Electronic Pressure-Independent Control Valve - VP3UB2F080C.111621 Electronic Pressure-Independent Control Valve - VP3UB2F100C.111621 Electronic Pressure-Independent Control Valve - VP3UB2F150C.111621 Electronic Pressure-Independent Control Valve

VP3000 Series Electronic Pressure-Independent Control Valves Catalog Page

Product name
VP3C2P20B.111601 Electronic Pressure-Independent Control Valve
VP3C2P20B.111621 Electronic Pressure-Independent Control Valve
VP3MB2D015C.111721 Electronic Pressure-Independent Control Valve
VP3MB2D020C.111721 Electronic Pressure-Independent Control Valve
VP3MB2D025C.111721 Electronic Pressure-Independent Control Valve
VP3MB2D032C.111721 Electronic Pressure-Independent Control Valve
VP3MB2D040C.111721 Electronic Pressure-Independent Control Valve
VP3MB2D050C.111721 Electronic Pressure-Independent Control Valve
VP3N6C15B.121001 Electronic Pressure-Independent Control Valve
VP3N6C15B.121601 Electronic Pressure-Independent Control Valve
VP3N6C25B.121001 Electronic Pressure-Independent Control Valve
VP3N6C25B.121601 Electronic Pressure-Independent Control Valve
VP3UB2F065C.111621 Electronic Pressure-Independent Control Valve
VP3UB2F080C.111621 Electronic Pressure-Independent Control Valve
VP3UB2F100C.111621 Electronic Pressure-Independent Control Valve
VP3UB2F150C.111621 Electronic Pressure-Independent Control Valve
Document type
Catalog Page
Document number
LIT-1901223
Revision date
2024-05-03
Product status
Active

VP3C2P20B

Figure 1. VP3C2P20B dimensions, mm

VP3N6xxxB

Figure 2. VP3N6C15B ceiling and floor mounting dimensions, mm

Figure 3. VP3N6C15B wall mounting dimensions, mm

Figure 4. VP3N6P25B ceiling and floor mounting dimensions, mm

Figure 5. VP3N6P25B wall mounting dimensions, mm

VP3MB2DxxxC

Figure 6. VP3MB2DxxxC.111721 dimensions, mm

Table 1. VP3MB2DxxxC dimensions table
Code number Dimension
L H H1 D/D1 H2 S1 B B1 S
VP3MB2D015C 304 108 168 1/2 in. 118 Min. 50 134 96 Min. 40
VP3MB2D020C 383 130 143 3/4 in. 120 97
VP3MB2D025C 410 129 145 D D1 121
3/4 in. 1 in.
VP3MB2D032C 431 132 151 D D1 125
3/4 in. 1 1/4 in.
VP3MB2D040C 498 144 168 D D1 130
1 1/4 in. 1 1/2 in.
VP3MB2D050C 513 143 181 D D1 143 101
1 1/4 in. 2 in.

VP3UB2FxxxC

Figure 7. VP3UB2FxxxC dimensions, mm

Table 2. VP3UB2FxxxC dimensions table
Code number Dimension
k2 d2 L H1 H2 L2 B1 b1 b2 D
Non-spring Spring Non-spring Spring
VP3UB2F065C 145 18 591 281 291 114 124 145 100 21 20 174
VP3UB2F080C 160 611 288 298 155 22 22 188
VP3UB2F100C 180 712 32 334 175 24 220
VP3UB2F150C 240 23 992 357 367 240 34 26 280