Selection charts - Johnson Controls - LIT-1900082 - Pneumatic Actuator - Threaded Globe Valve and Actuator - VG7000 Series Brass Trim Globe Valves with V-3000 Pneumatic Actuators

VG7000 Series Brass Trim Globe Valves with V-3000 Pneumatic Actuators Catalog Page

Product name
VG7000 Series Brass Trim Globe Valves with V-3000 Pneumatic Actuators
Document type
Catalog Page
Document number
LIT-1900082
Revision date
2020-07-17
Table 1. VG7000 Series Valve Assemblies with V-3000-8012 Exposed Pneumatic Actuators
Actuator code number V-3000-8012
Mounting Kit 1/2 in. and 3/4 in. VG7000-1001 VG7000-1002 VG7000-1003
1 in. and 1-1/4 in. VG7000-1004 VG7000-1005 VG7000-1006
1-1/2 in. and 2 in. VG7000-1007 VG7000-1008 VG7000-1009
Spring range 3 psig to 6 psig 4 psig to 8 psig 9 psig to 13 psig
Valve code number Size, in. Cv Closeoff psig Code number Closeoff psig Code number Closeoff psig Code number

Two-way normally open — NPT end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7241CT

1/2

0.73

365

VG7241CT+3008B

339

VG7241CT+3008D

191

VG7241CT+3008E

VG7241ET

1/2

1.8

365

VG7241ET+3008B

339

VG7241ET+3008D

191

VG7241ET+3008E

VG7241GT

1/2

4.6

225

VG7241GT+3008B

192

VG7241GT+3008D

108

VG7241GT+3008E

VG7241LT

3/4

7.3

144

VG7241LT+3008B

122

VG7241LT+3008D

69

VG7241LT+3008E

VG7241NT

1

11.6

90

VG7241NT+3008B

76

VG7241NT+3008D

42

VG7241NT+3008E

VG7241PT

1-1/4

18.5

55

VG7241PT+3008B

47

VG7241PT+3008D

26

VG7241PT+3008E

VG7241RT

1-1/2

28.9

35

VG7241RT+3008B

30

VG7241RT+3008D

16

VG7241RT+3008E

VG7241ST

2

46.2

22

VG7241ST+3008B

19

VG7241ST+3008D

11

VG7241ST+3008E

Two-way normally closed — NPT end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7441CT

1/2

0.73

100

VG7441CT+3008B

142

VG7441CT+3008D

348

VG7441CT+3008E

VG7441ET

1/2

1.8

100

VG7441ET+3008B

142

VG7441ET+3008D

348

VG7441ET+3008E

VG7441GT

1/2

4.6

49

VG7441GT+3008B

68

VG7441GT+3008D

168

VG7441GT+3008E

VG7441LT

3/4

7.3

29

VG7441LT+3008B

41

VG7441LT+3008D

100

VG7441LT+3008E

VG7441NT

1

11.6

17

VG7441NT+3008B

25

VG7441NT+3008D

65

VG7441NT+3008E

VG7441PT

1-1/4

18.5

10

VG7441PT+3008B

14

VG7441PT+3008D

37

VG7441PT+3008E

VG7441RT

1-1/2

28.9

6

VG7441RT+3008B

9

VG7441RT+3008D

23

VG7441RT+3008E

VG7441ST

2

46.2

4

VG7441ST+3008B

6

VG7441ST+3008D

14

VG7441ST+3008E

Three-way mixing — NPT end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7842CT

1/2

0.73

365 / 100

VG7842CT+3008B

339 / 142

VG7842CT+3008D

191 / 348

VG7842CT+3008E

VG7842ET

1/2

1.8

365 / 100

VG7842ET+3008B

339 / 142

VG7842ET+3008D

191 / 348

VG7842ET+3008E

VG7842GT

1/2

4.6

225 / 49

VG7842GT+3008B

192 / 68

VG7842GT+3008D

108 / 168

VG7842GT+3008E

VG7842LT

3/4

7.3

144 / 29

VG7842LT+3008B

122 / 41

VG7842LT+3008D

69 / 100

VG7842LT+3008E

VG7842NT

1

11.6

90 / 17

VG7842NT+3008B

76 / 25

VG7842NT+3008D

42 / 65

VG7842NT+3008E

VG7842PT

1-1/4

18.5

55 / 10

VG7842PT+3008B

47 / 14

VG7842PT+3008D

26 / 37

VG7842PT+3008E

VG7842RT

1-1/2

28.9

35 / 6

VG7842RT+3008B

30 / 9

VG7842RT+3008D

16 / 23

VG7842RT+3008E

VG7842ST

2

46.2

22 / 4

VG7842ST+3008B

19 / 6

VG7842ST+3008D

11 / 14

VG7842ST+3008E

Two-way normally open — union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7281CT

1/2

0.73

365

VG7281CT+3008B

339

VG7281CT+3008D

191

VG7281CT+3008E

VG7281ET

1/2

1.8

365

VG7281ET+3008B

339

VG7281ET+3008D

191

VG7281ET+3008E

VG7281GT

1/2

4.6

225

VG7281GT+3008B

192

VG7281GT+3008D

108

VG7281GT+3008E

VG7281LT

3/4

7.3

144

VG7281LT+3008B

122

VG7281LT+3008D

69

VG7281LT+3008E

VG7281NT

1

11.6

90

VG7281NT+3008B

76

VG7281NT+3008D

42

VG7281NT+3008E

VG7281PT

1-1/4

18.5

55

VG7281PT+3008B

47

VG7281PT+3008D

26

VG7281PT+3008E

VG7281RT

1-1/2

28.9

35

VG7281RT+3008B

30

VG7281RT+3008D

16

VG7281RT+3008E

VG7281ST

2

46.2

22

VG7281ST+3008B

19

VG7281ST+3008D

11

VG7281ST+3008E

Two-way normally closed — union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7481CT

1/2

0.73

100

VG7481CT+3008B

142

VG7481CT+3008D

348

VG7481CT+3008E

VG7481ET

1/2

1.8

100

VG7481ET+3008B

142

VG7481ET+3008D

348

VG7481ET+3008E

VG7481GT

1/2

4.6

49

VG7481GT+3008B

68

VG7481GT+3008D

168

VG7481GT+3008E

VG7481LT

3/4

7.3

29

VG7481LT+3008B

41

VG7481LT+3008D

100

VG7481LT+3008E

VG7481NT

1

11.6

17

VG7481NT+3008B

25

VG7481NT+3008D

65

VG7481NT+3008E

VG7481PT

1-1/4

18.5

10

VG7481PT+3008B

14

VG7481PT+3008D

37

VG7481PT+3008E

VG7481RT

1-1/2

28.9

6

VG7481RT+3008B

9

VG7481RT+3008D

23

VG7481RT+3008E

VG7481ST

2

46.2

4

VG7481ST+3008B

6

VG7481ST+3008D

14

VG7481ST+3008E

Three-way mixing — union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7882CT

1/2

0.73

365 / 100

VG7882CT+3008B

339 / 142

VG7882CT+3008D

191 / 348

VG7882CT+3008E

VG7882ET

1/2

1.8

365 / 100

VG7882ET+3008B

339 / 142

VG7882ET+3008D

191 / 348

VG7882ET+3008E

VG7882GT

1/2

4.6

225 / 49

VG7882GT+3008B

192 / 68

VG7882GT+3008D

108 / 168

VG7882GT+3008E

VG7882LT

3/4

7.3

144 / 29

VG7882LT+3008B

122 / 41

VG7882LT+3008D

69 / 100

VG7882LT+3008E

VG7882NT

1

11.6

90 / 17

VG7882NT+3008B

76 / 25

VG7882NT+3008D

42 / 65

VG7882NT+3008E

VG7882PT

1-1/4

18.5

55 / 10

VG7882PT+3008B

47 / 14

VG7882PT+3008D

26 / 37

VG7882PT+3008E

VG7882RT

1-1/2

28.9

35 / 6

VG7882RT+3008B

30 / 9

VG7882RT+3008D

16 / 23

VG7882RT+3008E

VG7882ST

2

46.2

22 / 4

VG7882ST+3008B

19 / 6

VG7882ST+3008D

11 / 14

VG7882ST+3008E

Two-way normally open — 3/8 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7271CT

1/2

0.73

365

VG7271CT+3008B

339

VG7271CT+3008D

191

VG7271CT+3008E

VG7271ET

1/2

1.8

365

VG7271ET+3008B

339

VG7271ET+3008D

191

VG7271ET+3008E

VG7271GT

1/2

4.6

225

VG7271GT+3008B

192

VG7271GT+3008D

108

VG7271GT+3008E

Two-way normally closed — 3/8 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7471CT

1/2

0.73

100

VG7471CT+3008B

142

VG7471CT+3008D

348

VG7471CT+3008E

VG7471ET

1/2

1.8

100

VG7471ET+3008B

142

VG7471ET+3008D

348

VG7471ET+3008E

VG7471GT

1/2

4.6

49

VG7471GT+3008B

68

VG7471GT+3008D

168

VG7471GT+3008E

Three-way mixing — 3/8 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7872CT

1/2

0.73

365 / 100

VG7872CT+3008B

339 / 142

VG7872CT+3008D

191 / 348

VG7872CT+3008E

VG7872ET

1/2

1.8

365 / 100

VG7872ET+3008B

339 / 142

VG7872ET+3008D

191 / 348

VG7872ET+3008E

VG7872GT

1/2

4.6

225 / 49

VG7872GT+3008B

192 / 68

VG7872GT+3008D

108 / 168

VG7872GT+3008E

Two-Way normally open — 3/4 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7291CT

1/2

0.73

365

VG7291CT+3008B

339

VG7291CT+3008D

191

VG7291CT+3008E

VG7291ET

1/2

1.8

365

VG7291ET+3008B

339

VG7291ET+3008D

191

VG7291ET+3008E

VG7291GT

1/2

4.6

225

VG7291GT+3008B

192

VG7291GT+3008D

108

VG7291GT+3008E

Two-way normally closed — 3/4 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7491CT

1/2

0.73

100

VG7491CT+3008B

142

VG7491CT+3008D

348

VG7491CT+3008E

VG7491ET

1/2

1.8

100

VG7491ET+3008B

142

VG7491ET+3008D

348

VG7491ET+3008E

VG7491GT

1/2

4.6

49

VG7491GT+3008B

68

VG7491GT+3008D

168

VG7491GT+3008E

Three-way mixing — 3/4 in. union sweat end connections (To specify a factory-mounted pneumatic postioner, add a P to the end of the code number.)

VG7892CT

1/2

0.73

365 / 100

VG7892CT+3008B

339 / 142

VG7892CT+3008D

191 / 348

VG7892CT+3008E

VG7892ET

1/2

1.8

365 / 100

VG7892ET+3008B

339 / 142

VG7892ET+3008D

191 / 348

VG7892ET+3008E

VG7892GT

1/2

4.6

225 / 49

VG7892GT+3008B

192 / 68

VG7892GT+3008D

108 / 168

VG7892GT+3008E

Two-way normally open — union globe end connections (no positioner option available)

VG7251CT

1/2

0.73

365

VG7251CT+3008B

339

VG7251CT+3008D

191

VG7251CT+3008E

VG7251ET

1/2

1.8

365

VG7251ET+3008B

339

VG7251ET+3008D

191

VG7251ET+3008E

VG7251GT

1/2

4.6

225

VG7251GT+3008B

192

VG7251GT+3008D

108

VG7251GT+3008E

VG7251LT

3/4

7.3

144

VG7251LT+3008B

122

VG7251LT+3008D

69

VG7251LT+3008E

VG7251NT

1

11.6

90

VG7251NT+3008B

76

VG7251NT+3008D

42

VG7251NT+3008E

VG7251PT

1-1/4

18.5

55

VG7251PT+3008B

47

VG7251PT+3008D

26

VG7251PT+3008E

VG7251RT

1-1/2

28.9

35

VG7251RT+3008B

30

VG7251RT+3008D

16

VG7251RT+3008E

Two-way normally closed — union globe end connections (no positioner option available)

VG7451CT

1/2

0.73

100

VG7451CT+3008B

142

VG7451CT+3008D

348

VG7451CT+3008E

VG7451ET

1/2

1.8

100

VG7451ET+3008B

142

VG7451ET+3008D

348

VG7451ET+3008E

VG7451GT

1/2

4.6

49

VG7451GT+3008B

68

VG7451GT+3008D

168

VG7451GT+3008E

Two-way normally open — union angle end connections (no positioner option available)

VG7551CT

1/2

0.73

365

VG7551CT+3008B

339

VG7551CT+3008D

191

VG7551CT+3008E

VG7551ET

1/2

1.8

365

VG7551ET+3008B

339

VG7551ET+3008D

191

VG7551ET+3008E

VG7551GT

1/2

4.6

225

VG7551GT+3008B

192

VG7551GT+3008D

108

VG7551GT+3008E

VG7551LT

3/4

7.3

144

VG7551LT+3008B

122

VG7551LT+3008D

69

VG7551LT+3008E

VG7551NT

1

11.6

90

VG7551NT+3008B

76

VG7551NT+3008D

42

VG7551NT+3008E

VG7551PT

1-1/4

18.5

55

VG7551PT+3008B

47

VG7551PT+3008D

26

VG7551PT+3008E

VG7551RT

1-1/2

28.9

35

VG7551RT+3008B

30

VG7551RT+3008D

16

VG7551RT+3008E

Table 2. VG7000 Series Valve Assemblies with V-3000-8003 Enclosed Pneumatic Actuators
Actuator code number V-3000-8003
Mounting kit 1/2 in. and 3/4 in. VG7000-1001 VG7000-1002 VG7000-1003
1 in. and 1-1/4 in. VG7000-1004 VG7000-1005 VG7000-1006
1-1/2 in. and 2 in. VG7000-1007 VG7000-1008 VG7000-1009
Spring range 3 psig to 6 psig 4 psig to 8 psig 9 psig to 13 psig
Valve code number Size, in. Cv Closeoff psig Code number Closeoff psig Code number Closeoff psig Code number

Two-way normally open — NPT end connections

VG7241CT

1/2

0.73

365

VG7241CT+3003B

339

VG7241CT+3003D

191

VG7241CT+3003E

VG7241ET

1/2

1.8

365

VG7241ET+3003B

339

VG7241ET+3003D

191

VG7241ET+3003E

VG7241GT

1/2

4.6

225

VG7241GT+3003B

192

VG7241GT+3003D

108

VG7241GT+3003E

VG7241LT

3/4

7.3

144

VG7241LT+3003B

122

VG7241LT+3003D

69

VG7241LT+3003E

VG7241NT

1

11.6

90

VG7241NT+3003B

76

VG7241NT+3003D

42

VG7241NT+3003E

VG7241PT

1-1/4

18.5

55

VG7241PT+3003B

47

VG7241PT+3003D

26

VG7241PT+3003E

VG7241RT

1-1/2

28.9

35

VG7241RT+3003B

30

VG7241RT+3003D

16

VG7241RT+3003E

VG7241ST

2

46.2

22

VG7241ST+3003B

19

VG7241ST+3003D

11

VG7241ST+3003E

Two-way normally closed — NPT end connections

VG7441CT

1/2

0.73

100

VG7441CT+3003B

142

VG7441CT+3003D

348

VG7441CT+3003E

VG7441ET

1/2

1.8

100

VG7441ET+3003B

142

VG7441ET+3003D

348

VG7441ET+3003E

VG7441GT

1/2

4.6

49

VG7441GT+3003B

68

VG7441GT+3003D

168

VG7441GT+3003E

VG7441LT

3/4

7.3

29

VG7441LT+3003B

41

VG7441LT+3003D

100

VG7441LT+3003E

VG7441NT

1

11.6

17

VG7441NT+3003B

25

VG7441NT+3003D

65

VG7441NT+3003E

VG7441PT

1-1/4

18.5

10

VG7441PT+3003B

14

VG7441PT+3003D

37

VG7441PT+3003E

VG7441RT

1-1/2

28.9

6

VG7441RT+3003B

9

VG7441RT+3003D

23

VG7441RT+3003E

VG7441ST

2

46.2

4

VG7441ST+3003B

6

VG7441ST+3003D

14

VG7441ST+3003E

Three-way mixing — NPT end connections

VG7842CT

1/2

0.73

365 / 100

VG7842CT+3003B

339 / 142

VG7842CT+3003D

191 / 348

VG7842CT+3003E

VG7842ET

1/2

1.8

365 / 100

VG7842ET+3003B

339 / 142

VG7842ET+3003D

191 / 348

VG7842ET+3003E

VG7842GT

1/2

4.6

225 / 49

VG7842GT+3003B

192 / 68

VG7842GT+3003D

108 / 168

VG7842GT+3003E

VG7842LT

3/4

7.3

144 / 29

VG7842LT+3003B

122 / 41

VG7842LT+3003D

69 / 100

VG7842LT+3003E

VG7842NT

1

11.6

90 / 17

VG7842NT+3003B

76 / 25

VG7842NT+3003D

42 / 65

VG7842NT+3003E

VG7842PT

1-1/4

18.5

55 / 10

VG7842PT+3003B

47 / 14

VG7842PT+3003D

26 / 37

VG7842PT+3003E

VG7842RT

1-1/2

28.9

35 / 6

VG7842RT+3003B

30 / 9

VG7842RT+3003D

16 / 23

VG7842RT+3003E

VG7842ST

2

46.2

22 / 4

VG7842ST+3003B

19 / 6

VG7842ST+3003D

11 / 14

VG7842ST+3003E

Two-way normally open — union sweat end connections

VG7281CT

1/2

0.73

365

VG7281CT+3003B

339

VG7281CT+3003D

191

VG7281CT+3003E

VG7281ET

1/2

1.8

365

VG7281ET+3003B

339

VG7281ET+3003D

191

VG7281ET+3003E

VG7281GT

1/2

4.6

225

VG7281GT+3003B

192

VG7281GT+3003D

108

VG7281GT+3003E

VG7281LT

3/4

7.3

144

VG7281LT+3003B

122

VG7281LT+3003D

69

VG7281LT+3003E

VG7281NT

1

11.6

90

VG7281NT+3003B

76

VG7281NT+3003D

42

VG7281NT+3003E

VG7281PT

1-1/4

18.5

55

VG7281PT+3003B

47

VG7281PT+3003D

26

VG7281PT+3003E

VG7281RT

1-1/2

28.9

35

VG7281RT+3003B

30

VG7281RT+3003D

16

VG7281RT+3003E

VG7281ST

2

46.2

22

VG7281ST+3003B

19

VG7281ST+3003D

11

VG7281ST+3003E

Two-way normally closed — union sweat end connections

VG7481CT

1/2

0.73

100

VG7481CT+3003B

142

VG7481CT+3003D

348

VG7481CT+3003E

VG7481ET

1/2

1.8

100

VG7481ET+3003B

142

VG7481ET+3003D

348

VG7481ET+3003E

VG7481GT

1/2

4.6

49

VG7481GT+3003B

68

VG7481GT+3003D

168

VG7481GT+3003E

VG7481LT

3/4

7.3

29

VG7481LT+3003B

41

VG7481LT+3003D

100

VG7481LT+3003E

VG7481NT

1

11.6

17

VG7481NT+3003B

25

VG7481NT+3003D

65

VG7481NT+3003E

VG7481PT

1-1/4

18.5

10

VG7481PT+3003B

14

VG7481PT+3003D

37

VG7481PT+3003E

VG7481RT

1-1/2

28.9

6

VG7481RT+3003B

9

VG7481RT+3003D

23

VG7481RT+3003E

VG7481ST

2

46.2

4

VG7481ST+3003B

6

VG7481ST+3003D

14

VG7481ST+3003E

Three-way mixing — union sweat end connections

VG7882CT

1/2

0.73

365 / 100

VG7882CT+3003B

339 / 142

VG7882CT+3003D

191 / 348

VG7882CT+3003E

VG7882ET

1/2

1.8

365 / 100

VG7882ET+3003B

339 / 142

VG7882ET+3003D

191 / 348

VG7882ET+3003E

VG7882GT

1/2

4.6

225 / 49

VG7882GT+3003B

192 / 68

VG7882GT+3003D

108 / 168

VG7882GT+3003E

VG7882LT

3/4

7.3

144 / 29

VG7882LT+3003B

122 / 41

VG7882LT+3003D

69 / 100

VG7882LT+3003E

VG7882NT

1

11.6

90 / 17

VG7882NT+3003B

76 / 25

VG7882NT+3003D

42 / 65

VG7882NT+3003E

VG7882PT

1-1/4

18.5

55 / 10

VG7882PT+3003B

47 / 14

VG7882PT+3003D

26 / 37

VG7882PT+3003E

VG7882RT

1-1/2

28.9

35 / 6

VG7882RT+3003B

30 / 9

VG7882RT+3003D

16 / 23

VG7882RT+3003E

VG7882ST

2

46.2

22 / 4

VG7882ST+3003B

19 / 6

VG7882ST+3003D

11 / 14

VG7882ST+3003E

Two-way normally open — 3/8 in. union sweat end connections

VG7271CT

1/2

0.73

365

VG7271CT+3003B

339

VG7271CT+3003D

191

VG7271CT+3003E

VG7271ET

1/2

1.8

365

VG7271ET+3003B

339

VG7271ET+3003D

191

VG7271ET+3003E

VG7271GT

1/2

4.6

225

VG7271GT+3003B

192

VG7271GT+3003D

108

VG7271GT+3003E

Two-way normally closed — 3/8 in. union sweat end connections

VG7471CT

1/2

0.73

100

VG7471CT+3003B

142

VG7471CT+3003D

348

VG7471CT+3003E

VG7471ET

1/2

1.8

100

VG7471ET+3003B

142

VG7471ET+3003D

348

VG7471ET+3003E

VG7471GT

1/2

4.6

49

VG7471GT+3003B

68

VG7471GT+3003D

168

VG7471GT+3003E

Three-way mixing — 3/8 in. union sweat end connections

VG7872CT

1/2

0.73

365 / 100

VG7872CT+3003B

339 / 142

VG7872CT+3003D

191 / 348

VG7872CT+3003E

VG7872ET

1/2

1.8

365 / 100

VG7872ET+3003B

339 / 142

VG7872ET+3003D

191 / 348

VG7872ET+3003E

VG7872GT

1/2

4.6

225 / 49

VG7872GT+3003B

192 / 68

VG7872GT+3003D

108 / 168

VG7872GT+3003E

Two-way normally open — 3/4 in. union sweat end connections

VG7291CT

1/2

0.73

365

VG7291CT+3003B

339

VG7291CT+3003D

191

VG7291CT+3003E

VG7291ET

1/2

1.8

365

VG7291ET+3003B

339

VG7291ET+3003D

191

VG7291ET+3003E

VG7291GT

1/2

4.6

225

VG7291GT+3003B

192

VG7291GT+3003D

108

VG7291GT+3003E

Two-way normally closed — 3/4 in. union sweat end connections

VG7491CT

1/2

0.73

100

VG7491CT+3003B

142

VG7491CT+3003D

348

VG7491CT+3003E

VG7491ET

1/2

1.8

100

VG7491ET+3003B

142

VG7491ET+3003D

348

VG7491ET+3003E

VG7491GT

1/2

4.6

49

VG7491GT+3003B

68

VG7491GT+3003D

168

VG7491GT+3003E

Three-way mixing — 3/4 in. union sweat end connections

VG7892CT

1/2

0.73

365 / 100

VG7892CT+3003B

339 / 142

VG7892CT+3003D

191 / 348

VG7892CT+3003E

VG7892ET

1/2

1.8

365 / 100

VG7892ET+3003B

339 / 142

VG7892ET+3003D

191 / 348

VG7892ET+3003E

VG7892GT

1/2

4.6

225 / 49

VG7892GT+3003B

192 / 68

VG7892GT+3003D

108 / 168

VG7892GT+3003E

Two-way normally open — union globe end connections

VG7251CT

1/2

0.73

365

VG7251CT+3003B

339

VG7251CT+3003D

191

VG7251CT+3003E

VG7251ET

1/2

1.8

365

VG7251ET+3003B

339

VG7251ET+3003D

191

VG7251ET+3003E

VG7251GT

1/2

4.6

225

VG7251GT+3003B

192

VG7251GT+3003D

108

VG7251GT+3003E

VG7251LT

3/4

7.3

144

VG7251LT+3003B

122

VG7251LT+3003D

69

VG7251LT+3003E

VG7251NT

1

11.6

90

VG7251NT+3003B

76

VG7251NT+3003D

42

VG7251NT+3003E

VG7251PT

1-1/4

18.5

55

VG7251PT+3003B

47

VG7251PT+3003D

26

VG7251PT+3003E

VG7251RT

1-1/2

28.9

35

VG7251RT+3003B

30

VG7251RT+3003D

16

VG7251RT+3003E

Two-way normally closed — union globe end connections

VG7451CT

1/2

0.73

100

VG7451CT+3003B

142

VG7451CT+3003D

348

VG7451CT+3003E

VG7451ET

1/2

1.8

100

VG7451ET+3003B

142

VG7451ET+3003D

348

VG7451ET+3003E

VG7451GT

1/2

4.6

49

VG7451GT+3003B

68

VG7451GT+3003D

168

VG7451GT+3003E

Two-way normally open — union angle end connections

VG7551CT

1/2

0.73

365

VG7551CT+3003B

339

VG7551CT+3003D

191

VG7551CT+3003E

VG7551ET

1/2

1.8

365

VG7551ET+3003B

339

VG7551ET+3003D

191

VG7551ET+3003E

VG7551GT

1/2

4.6

225

VG7551GT+3003B

192

VG7551GT+3003D

108

VG7551GT+3003E

VG7551LT

3/4

7.3

144

VG7551LT+3003B

122

VG7551LT+3003D

69

VG7551LT+3003E

VG7551NT

1

11.6

90

VG7551NT+3003B

76

VG7551NT+3003D

42

VG7551NT+3003E

VG7551PT

1-1/4

18.5

55

VG7551PT+3003B

47

VG7551PT+3003D

26

VG7551PT+3003E

VG7551RT

1-1/2

28.9

35

VG7551RT+3003B

30

VG7551RT+3003D

16

VG7551RT+3003E