Table 1. Two-way — spring return valves — without switches (not rated for steam service)
Fluid temperatures:-22 to 212°F (-30 to 100°C)

not rated for steam service

AC 24 V AC 85–264 V (VA9203)

AC 120 V (VA9208)

Valve Size, in. Cv Characterizing disk Closeoff psig Floating DC 0 to 10 V proportional On/off On/off
 

Spring return open — valve normally open

VA9203-AGA-2Z

VA9203-GGA-2Z

VA9203-BGA-2

VA9203-BUA-2

VG1245AA

1/2

0.3 Yes

200

VG1245AA+923AGA

VG1245AA+923GGA

VG1245AA+923BGA

-
VG1245AB 0.5 Yes

VG1245AB+923AGA

VG1245AB+923GGA

VG1245AB+923BGA

-
VG1245AC 0.8 Yes

VG1245AC+923AGA

VG1245AC+923GGA

VG1245AC+923BGA

-

VG1245AD

1.2

Yes

VG1245AD+923AGA

VG1245AD+923GGA

VG1245AD+923BGA

VG1245AD+923BUA

VG1245AE

1.9

Yes

VG1245AE+923AGA

VG1245AE+923GGA

VG1245AE+923BGA

VG1245AE+923BUA

VG1245AF

2.9

Yes

VG1245AF+923AGA

VG1245AF+923GGA

VG1245AF+923BGA

VG1245AF+923BUA

VG1245AG

4.7

Yes

VG1245AG+923AGA

VG1245AG+923GGA

VG1245AG+923BGA

VG1245AG+923BUA

VG1245AL

7.4

Yes

VG1245AL+923AGA

VG1245AL+923GGA

VG1245AL+923BGA

VG1245AL+923BUA

VG1245AN

11.7

No

VG1245AN+923AGA

VG1245AN+923GGA

VG1245AN+923BGA

VG1245AN+923BUA

VG1245BG

3/4

4.7

Yes

200

VG1245BG+923AGA

VG1245BG+923GGA

VG1245BG+923BGA

VG1245BG+923BUA

VG1245BL

7.4

Yes

VG1245BL+923AGA

VG1245BL+923GGA

VG1245BL+923BGA

VG1245BL+923BUA

VG1245BN

11.7

No

VG1245BN+923AGA

VG1245BN+923GGA

VG1245BN+923BGA

VG1245BN+923BUA

VG1245CL

1

7.4

Yes

200

VG1245CL+923AGA

VG1245CL+923GGA

VG1245CL+923BGA

VG1245CL+923BUA

VG1245CN

11.7

Yes

VG1245CN+923AGA

VG1245CN+923GGA

VG1245CN+923BGA

VG1245CN+923BUA

VG1245CP

18.7

No

VG1245CP+923AGA

VG1245CP+923GGA

VG1245CP+923BGA

VG1245CP+923BUA

 

Spring return open — valve normally open

VA9208-AGA-2

VA9208-GGA-2

VA9208-BGA-3

VA9208-BAA-3

VG1245DN

1-1/4

11.7

Yes

200

VG1245DN+928AGA

VG1245DN+928GGA

VG1245DN+938BGA

VG1245DN+938BAA

VG1245DP

18.7

Yes

VG1245DP+928AGA

VG1245DP+928GGA

VG1245DP+938BGA

VG1245DP+938BAA

VG1245DR

29.2

No

VG1245DR+928AGA

VG1245DR+928GGA

VG1245DR+938BGA

VG1245DR+938BAA

VG1245EP

1-1/2

18.7

Yes

200

VG1245EP+928AGA

VG1245EP+928GGA

VG1245EP+938BGA

VG1245EP+938BAA

VG1245ER

29.2

Yes

VG1245ER+928AGA

VG1245ER+928GGA

VG1245ER+938BGA

VG1245ER+938BAA

VG1245ES

46.8

No

VG1245ES+928AGA

VG1245ES+928GGA

VG1245ES+938BGA

VG1245ES+938BAA

VG1245FR

2

29.2

Yes

200

VG1245FR+928AGA

VG1245FR+928GGA

VG1245FR+938BGA

VG1245FR+938BAA

VG1245FS

46.8

Yes

VG1245FS+928AGA

VG1245FS+928GGA

VG1245FS+938BGA

VG1245FS+938BAA

VG1245FT

73.7

No

VG1245FT+928AGA

VG1245FT+928GGA

VG1245FT+938BGA

VG1245FT+938BAA

 

Spring return closed — valve normally closed

VA9203-AGA-2Z

VA9203-GGA-2Z

VA9203-BGA-2

VA9203-BUA-2

VG1245AA

1/2

0.3 Yes

200

VG1245AA+943AGA

VG1245AA+943GGA

VG1245AA+943BGA

-
VG1245AB 0.5 Yes

VG1245AB+943AGA

VG1245AB+943GGA

VG1245AB+943BGA

-
VG1245AC 0.8 Yes

VG1245AC+943AGA

VG1245AC+943GGA

VG1245AC+943BGA

-

VG1245AD

1.2

Yes

VG1245AD+943AGA

VG1245AD+943GGA

VG1245AD+943BGA

VG1245AD+943BUA

VG1245AE

1.9

Yes

VG1245AE+943AGA

VG1245AE+943GGA

VG1245AE+943BGA

VG1245AE+943BUA

VG1245AF

2.9

Yes

VG1245AF+943AGA

VG1245AF+943GGA

VG1245AF+943BGA

VG1245AF+943BUA

VG1245AG

4.7

Yes

VG1245AG+943AGA

VG1245AG+943GGA

VG1245AG+943BGA

VG1245AG+943BUA

VG1245AL

7.4

Yes

VG1245AL+943AGA

VG1245AL+943GGA

VG1245AL+943BGA

VG1245AL+943BUA

VG1245AN

11.7

No

VG1245AN+943AGA

VG1245AN+943GGA

VG1245AN+943BGA

VG1245AN+943BUA

VG1245BG

3/4

4.7

Yes

200

VG1245BG+943AGA

VG1245BG+943GGA

VG1245BG+943BGA

VG1245BG+943BUA

VG1245BL

7.4

Yes

VG1245BL+943AGA

VG1245BL+943GGA

VG1245BL+943BGA

VG1245BL+943BUA

VG1245BN

11.7

No

VG1245BN+943AGA

VG1245BN+943GGA

VG1245BN+943BGA

VG1245BN+943BUA

VG1245CL

1

7.4

Yes

200

VG1245CL+943AGA

VG1245CL+943GGA

VG1245CL+943BGA

VG1245CL+943BUA

VG1245CN

11.7

Yes

VG1245CN+943AGA

VG1245CN+943GGA

VG1245CN+943BGA

VG1245CN+943BUA

VG1245CP

18.7

No

VG1245CP+943AGA

VG1245CP+943GGA

VG1245CP+943BGA

VG1245CP+943BUA

 

Spring return closed — valve normally closed

VA9208-AGA-2

VA9208-GGA-2

VA9208-BGA-3

VA9208-BAA-3

VG1245DN

1-1/4

11.7

Yes

200

VG1245DN+948AGA

VG1245DN+948GGA

VG1245DN+958BGA

VG1245DN+958BAA

VG1245DP

18.7

Yes

VG1245DP+948AGA

VG1245DP+948GGA

VG1245DP+958BGA

VG1245DP+958BAA

VG1245DR

29.2

No

VG1245DR+948AGA

VG1245DR+948GGA

VG1245DR+958BGA

VG1245DR+958BAA

VG1245EP

1-1/2

18.7

Yes

200

VG1245EP+948AGA

VG1245EP+948GGA

VG1245EP+958BGA

VG1245EP+958BAA

VG1245ER

29.2

Yes

VG1245ER+948AGA

VG1245ER+948GGA

VG1245ER+958BGA

VG1245ER+958BAA

VG1245ES

46.8

No

VG1245ES+948AGA

VG1245ES+948GGA

VG1245ES+958BGA

VG1245ES+958BAA

VG1245FR

2

29.2

Yes

200

VG1245FR+948AGA

VG1245FR+948GGA

VG1245FR+958BGA

VG1245FR+958BAA

VG1245FS

46.8

Yes

VG1245FS+948AGA

VG1245FS+948GGA

VG1245FS+958BGA

VG1245FS+958BAA

VG1245FT

73.7

No

VG1245FT+948AGA

VG1245FT+948GGA

VG1245FT+958BGA

VG1245FT+958BAA

Table 2. Valve assemblies with M9000-561 Thermal Barrier installed — rated for high-temperature fluid service two-way — spring return valve open — normally open — without end switches
Fluid temperatures:-22 to 284°F (-30 to 140°C)

water and 15 psi steam

AC 24 V AC 85–264 V (VA9203)

AC 120 V (VA9208)

Valve Size, in. Cv Characterizing disk Closeoff psig Floating DC 0 to 10 V proportional On/off On/off
 

Spring return open — valve normally open

VA9203-AGA-2Z

VA9203-GGA-2Z

VA9203-BGA-2

VA9203-BUA-2

VG1245AA

1/2

0.3 Yes

200

VG1245AAH923AGA

VG1245AAH923GGA

VG1245AAH923BGA

-
VG1245AB 0.5 Yes

VG1245ABH923AGA

VG1245ABH923GGA

VG1245ABH923BGA

-
VG1245AC 0.8 Yes

VG1245ACH923AGA

VG1245ACH923GGA

VG1245ACH923BGA

-

VG1245AD

1.2

Yes

VG1245ADH923AGA

VG1245ADH923GGA

VG1245ADH923BGA

VG1245ADH923BUA

VG1245AE

1.9

Yes

VG1245AEH923AGA

VG1245AEH923GGA

VG1245AEH923BGA

VG1245AEH923BUA

VG1245AF

2.9

Yes

VG1245AFH923AGA

VG1245AFH923GGA

VG1245AFH923BGA

VG1245AFH923BUA

VG1245AG

4.7

Yes

VG1245AGH923AGA

VG1245AGH923GGA

VG1245AGH923BGA

VG1245AGH923BUA

VG1245AL

7.4

Yes

VG1245ALH923AGA

VG1245ALH923GGA

VG1245ALH923BGA

VG1245ALH923BUA

VG1245AN

11.7

No

VG1245ANH923AGA

VG1245ANH923GGA

VG1245ANH923BGA

VG1245ANH923BUA

VG1245BG

3/4

4.7

Yes

200

VG1245BGH923AGA

VG1245BGH923GGA

VG1245BGH923BGA

VG1245BGH923BUA

VG1245BL

7.4

Yes

VG1245BLH923AGA

VG1245BLH923GGA

VG1245BLH923BGA

VG1245BLH923BUA

VG1245BN

11.7

No

VG1245BNH923AGA

VG1245BNH923GGA

VG1245BNH923BGA

VG1245BNH923BUA

VG1245CL

1

7.4

Yes

200

VG1245CLH923AGA

VG1245CLH923GGA

VG1245CLH923BGA

VG1245CLH923BUA

VG1245CN

11.7

Yes

VG1245CNH923AGA

VG1245CNH923GGA

VG1245CNH923BGA

VG1245CNH923BUA

VG1245CP

18.7

No

VG1245CPH923AGA

VG1245CPH923GGA

VG1245CPH923BGA

VG1245CPH923BUA

 

Spring return open — valve normally open

VA9208-AGA-2

VA9208-GGA-2

VA9208-BGA-3

VA9208-BAA-3

VG1245DN

1-1/4

11.7

Yes

200

VG1245DNH928AGA

VG1245DNH928GGA

VG1245DNH938BGA

VG1245DNH938BAA

VG1245DP

18.7

Yes

VG1245DPH928AGA

VG1245DPH928GGA

VG1245DPH938BGA

VG1245DPH938BAA

VG1245DR

29.2

No

VG1245DRH928AGA

VG1245DRH928GGA

VG1245DRH938BGA

VG1245DRH938BAA

VG1245EP

1-1/2

18.7

Yes

200

VG1245EPH928AGA

VG1245EPH928GGA

VG1245EPH938BGA

VG1245EPH938BAA

VG1245ER

29.2

Yes

VG1245ERH928AGA

VG1245ERH928GGA

VG1245ERH938BGA

VG1245ERH938BAA

VG1245ES

46.8

No

VG1245ESH928AGA

VG1245ESH928GGA

VG1245ESH938BGA

VG1245ESH938BAA

VG1245FR

2

29.2

Yes

200

VG1245FRH928AGA

VG1245FRH928GGA

VG1245FRH938BGA

VG1245FRH938BAA

VG1245FS

46.8

Yes

VG1245FSH928AGA

VG1245FSH928GGA

VG1245FSH938BGA

VG1245FSH938BAA

VG1245FT

73.7

No

VG1245FTH928AGA

VG1245FTH928GGA

VG1245FTH938BGA

VG1245FTH938BAA

 

Spring return closed — valve normally closed

VA9203-AGA-2Z

VA9203-GGA-2Z

VA9203-BGA-2

VA9203-BUA-2

VG1245AA

1/2

0.3 Yes

200

VG1245AAH943AGA

VG1245AAH943GGA

VG1245AAH943BGA

-
VG1245AB 0.5 Yes

VG1245ABH943AGA

VG1245ABH943GGA

VG1245ABH943BGA

-
VG1245AC 0.8 Yes

VG1245ACH943AGA

VG1245ACH943GGA

VG1245ACH943BGA

-

VG1245AD

1.2 Yes

VG1245ADH943AGA

VG1245ADH943GGA

VG1245ADH943BGA

VG1245ADH943BUA

VG1245AE

1.9

Yes

VG1245AEH943AGA

VG1245AEH943GGA

VG1245AEH943BGA

VG1245AEH943BUA

VG1245AF

2.9

Yes

VG1245AFH943AGA

VG1245AFH943GGA

VG1245AFH943BGA

VG1245AFH943BUA

VG1245AG

4.7

Yes

VG1245AGH943AGA

VG1245AGH943GGA

VG1245AGH943BGA

VG1245AGH943BUA

VG1245AL

7.4

Yes

VG1245ALH943AGA

VG1245ALH943GGA

VG1245ALH943BGA

VG1245ALH943BUA

VG1245AN

11.7

No

VG1245ANH943AGA

VG1245ANH943GGA

VG1245ANH943BGA

VG1245ANH943BUA

VG1245BG

3/4

4.7

Yes

200

VG1245BGH943AGA

VG1245BGH943GGA

VG1245BGH943BGA

VG1245BGH943BUA

VG1245BL

7.4

Yes

VG1245BLH943AGA

VG1245BLH943GGA

VG1245BLH943BGA

VG1245BLH943BUA

VG1245BN

11.7

No

VG1245BNH943AGA

VG1245BNH943GGA

VG1245BNH943BGA

VG1245BNH943BUA

VG1245CL

1

7.4

Yes

200

VG1245CLH943AGA

VG1245CLH943GGA

VG1245CLH943BGA

VG1245CLH943BUA

VG1245CN

11.7

Yes

VG1245CNH943AGA

VG1245CNH943GGA

VG1245CNH943BGA

VG1245CNH943BUA

VG1245CP

18.7

No

VG1245CPH943AGA

VG1245CPH943GGA

VG1245CPH943BGA

VG1245CPH943BUA

 

Spring return closed — Valve normally closed

VA9208-AGA-2

VA9208-GGA-2

VA9208-BGA-3

VA9208-BAA-3

VG1245DN

1-1/4

11.7

Yes

200

VG1245DNH948AGA

VG1245DNH948GGA

VG1245DNH958BGA

VG1245DNH958BAA

VG1245DP

18.7

Yes

VG1245DPH948AGA

VG1245DPH948GGA

VG1245DPH958BGA

VG1245DPH958BAA

VG1245DR

29.2

No

VG1245DRH948AGA

VG1245DRH948GGA

VG1245DRH958BGA

VG1245DRH958BAA

VG1245EP

1-1/2

18.7

Yes

200

VG1245EPH948AGA

VG1245EPH948GGA

VG1245EPH958BGA

VG1245EPH958BAA

VG1245ER

29.2

Yes

VG1245ERH948AGA

VG1245ERH948GGA

VG1245ERH958BGA

VG1245ERH958BAA

VG1245ES

46.8

No

VG1245ESH948AGA

VG1245ESH948GGA

VG1245ESH958BGA

VG1245ESH958BAA

VG1245FR

2

29.2

Yes

200

VG1245FRH948AGA

VG1245FRH948GGA

VG1245FRH958BGA

VG1245FRH958BAA

VG1245FS

46.8

Yes

VG1245FSH948AGA

VG1245FSH948GGA

VG1245FSH958BGA

VG1245FSH958BAA

VG1245FT

73.7

No

VG1245FTH948AGA

VG1245FTH948GGA

VG1245FTH958BGA

VG1245FTH958BAA