Accessories - Johnson Controls - LIT-1924415 - Electric Actuator - VA-9070

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Catalog Page

Product name
VA-9070
Document type
Catalog Page
Document number
LIT-1924415
Revision date
2023-03-09
Accessories
Description Code number
Servo kit

For 120V models of VA-9070 Series Modulating Electric Actuators

For 24V models of VA-9070 Series Modulating Electric Actuators

VA-907x-630

VA-907x-634

Thermostat / heater kit For all models of VA-9070 Series Two-Position and Modulating Electric Actuators VA-907x-609
Mounting and adaptor kits for Standard‑Pressure, Standard‑Temperature Two‑Way VF Series Butterfly Valves Mounts VA-9071 Series Two-Position and Modulating Electric Actuators on 2 in. through 3 in. valves VA-9072-300
Mounts VA-9071 Series Two-Position and Modulating Electric Actuators on 4 in. valves VA-9072-400
Mounts VA-9071 / VA-9073 Series Two-Position and Modulating Electric Actuators on 5 in. and 6 in. valves VA-9072-600
Mounts VA-9075 Series Two-Position and Modulating Electric Actuators on 4 in. valves VA-9075-400
Mounts VA-9075 Series Two-Position and Modulating Electric Actuators on 5 in. and 6 in. valves VA-9075-600
Mounts VA-9074 / VA-9075/VA-9076 Series Two-Position and Modulating Electric Actuators on 8 in. valves VA-9075-800
Mounts VA-9075 / VA-9076 Series Two-Position and Modulating Electric Actuators on 10 in. and 12 in. valves VA-9075-1200
Mounts VA-9077 / VA-9078 Series Two-Position and Modulating Electric Actuators on 8 in. valves VA-9078-800
Mounts VA-9077, and VA-9078 Series Two-Position and Modulating Electric Actuators on 10 in. and 12 in. valves VA-9078-1200

Mounts VA-9077 / VA-9078 Series Two-Position and Modulating Electric Actuators on 14 in. and 16 in. valves

Mounts VA-907A Series Two-Position and Modulating Electric Actuators on 16 in. valves

VA-9078-1600

Mounts VA-9077 / VA-9078 Series Two-Position and Modulating Electric Actuators on 18 in. and 20 in. valves

Mounts VA-907A Series Two-Position and Modulating Electric Actuators on 18 in. valves

Mounts VA-907B Series Two-Position and Modulating Electric Actuators on 20 in. valves

VA-9078-2000
Mounting and adaptor kits for Class 150 High-Pressure, High‑Temperature Two‑Way VF Series Butterfly Valves Mounts VA-9071 Series Electric Actuators on 2 1/2 in. through 4 in. valves VA-9072-410
Mounts VA-9074 / VA-9075 Series Electric Actuators on 5 in. and 6 in. valves VA-9075-610
Mounts VA-9076 Series Electric Actuators on 8 in. valves VA-9075-800
Mounts VA-9077 Series Electric Actuators on 10 in. and VA-9078 Series Electric Actuators on 12 in. valves VA-9078-1210
Mounts VA-907A Series Electric Actuators on 14 in. valves VA-9078-1600
Mounts VA-907A Series Electric Actuators on 16 in. valves VA-9078-2000
Mounting and adaptor kits for Class 300 High-Pressure, High‑Temperature Two‑Way VF Series Butterfly Valves Mounts VA-9075 Series Electric Actuators on 2 1/2 in. through 4 in. valves VA-9075-430
Mounts VA-9075 Series Electric Actuators on 5 in. valves VA-9075-530
Mounts VA-9076 Series Electric Actuators on 6 in. valves VA-9075-630
Mounts VA-9077 Series Electric Actuators on 8 in. valves VA-9075-830
Mounts VA-907A Series Electric Actuators on 12 in. valves VA-9078-1600
Mounts VA-907B Series Electric Actuators on 14 in. valves VA-9078-2000
Local control station For all 120V models of VA-9070 Series Modulating Electric Actuators; kit includes local and remote control switch, open-stop-close switch, and two LEDs for position indication (green for open and red for closed) VA-907X-620
Auxiliary switch kits Single auxiliary switch for VA-9075 Series Modulating Electric Actuators VA-907X-601
Single auxiliary switch for VA-9076, VA-9077, and VA-9078 Series Modulating Electric Actuators VA-907X-602
Single auxiliary switch for VA-9075 Series Two-Position Electric Actuators VA-907X-603
Single auxiliary switch for VA-9076, VA-9077, and VA-9078 Series Two-Position Electric Actuators VA-907X-604
Two auxiliary switches for VA-9075 Series Two-Position Electric Actuators VA-907X-605
Two auxiliary switches for VA-9076, VA-9077, and VA-9078 Series Two-Position Electric Actuators VA-907X-606
Feedback potentiometer kits Feedback potentiometer kit, 5,000 Ohm, gear driven for VA-907x Series Proportional Non-Spring Return Electric Actuators VA-907X-615
VA-9070 Series Electric Rotary Actuators motor ratings and operating speeds

Actuator series:

Johnson Controls code number

(Bray series number)

50/60 Hz single phase motors: current rating in amperes at all speeds

Two-position and modulating speeds for 90° operation in seconds1

(Total gear ratio)

VAC Amperes
VA-9071 (071-0530) 120 0.4 31 seconds (38:5:1)
24 1.7 31 seconds
VA-9073 (S70-008) 120 0.8 30 seconds (30:1)
24 2.9 60 seconds
VA-9074 120 0.75 30 seconds
VA-9075 (S70-020) 120 0.85 30 seconds
24 3.5 80 seconds
VA-9076 (S70-030) 120 1 30 seconds (30:1)
VA-9077 (S70-050) 120 1.6 30 seconds (30:1)
24 4 90 seconds
VA-9078 (S70-065) 120 2.3 30 seconds (30:1)
VA-907A (S70-130) 120 2.3 110 seconds (90:1)
VA-907B (S70-180) 120 2.5 110 seconds (90:1)
VA-9070 Series Electric Rotary Actuators output torque values, rim pull, and mounting data

Actuator series:

Johnson Controls code number

(Bray series number)

Output torque lb·in (N·m) Rim pull lb (kg) Net weight lb (kg)
VA-9071 (S71-0530) 530 (60) 8.9 (4.0)
VA-9073 (S70-008) 800 (90) 22.8 (10.3) 13.0 (6.0)
VA-9074 (S70-012) 1,200 (135) 28.0 (13.0)
VA-9075 (S70-020) 2,000 (226) 33.0 (15.0) 28.0 (13.0)
VA-9076 (S70-030) 3,000 (339) 33.0 (15.0) 28.0 (13.0)
VA-9077 (S70-050) 5,000 (565) 55.0 (25.0) 48.0 (22.0)
VA-9078 (S70-065) 6,500 (734) 72.0 (32.7)
VA-907A (S70-130) 13,000 (1,470) 80.0 (36.2) 118.0 (54.0)
VA-907B (S70-180) 18,000 (2,030)
1 The continuous duty cycle for the two-position and modulating operation is 100% at a maximum ambient temperature of 150°F (65°C). The intermittent duty cycle for the two-position and modulating operation for the VA-9071 (Series 71) is 50% at a maximum ambient temperature of 250°F (120°C).