Selection chart - Johnson Controls - LIT-1900217 - TE-631AM-1 - TE-631AM-2 - TE-6327P-1 - TE-6352P-1 - TE-635GM-1 - TE-631GV-2 - TE-636NE-2 - TE-6311A-1 - TE-635AP-1 - TE-636GM-1 - TE-6315M-1 - TE-6311M-1 - TE-6313P-1 - TE-6341A-1 - TE-6351M-1 - TE-635JM-1 - TE-6353P-1 - TE-6361P-1 - TE-6351A-1 - TE-636ME-2 - TE-6361V-2 - TE-6343P-1 - TE-6360F-1 - TE-6360F-0 - TE-6362M-1 - TE-6316P-1 - TE-6337P-1 - TE-636JM-1 - TE-6312P-1 - TE-634GV-2 - TE-6316V-2 - TE-634AM-2 - TE-6352M-1 - TE-636AM-2 - TE-636AM-1 - TE-631AP-1 - TE-636GV-2 - TE-6369E-2 - TE-631GM-1 - TE-6350F-0 - TE-635AM-2 - TE-635AM-1 - TE-6341V-2 - TE-6350F-1 - TE-635S-1 - TE-6361E-2 - TE-631JM-1 - TE-6315P-1 - TE-635GV-2 - TE-631S-1 - TE-6338P-1 - TE-6342M-1 - TE-6344P-1 - TE-6361A-1 - TE-6363P-1 - TE-6311P-1 - TE-6361M-1 - TE-6351V-2 - TE-6315V-2 - TE-6311V-2 - TE-6351P-1 - TE-6328P-1 - TE-6324P-1 - TE-6316M-1 - TE-6310F-0 - TE-6310F-1 - TE-6341P-1 - TE-6312M-1 - TE-636S-1 - TE-6314P-1 - Temperature Sensor - TE-6300 Temperature Sensor

TE-6300 Series Temperature Sensors Catalog Page

Product
Sensors and Meters > Temperature Sensors > TE-6300 Temperature Sensor
Document number
LIT-1900217
Revision date
2019-10-13
Table 1. TE-6300 Temperature Sensor Models
Sensor Mounting Style Probe Length in. (mm) Product CodeNumber
Nickel (1k ohm) Adjustable 8 (203) TE-6311A-1
Averaging 1 8 ft (2.4 m) TE-6315M-1
TE-6315P-1
TE-6315V-2
17 ft (5.2 m) TE-6316M-1
TE-6316P-1
TE-6316V-2
Duct 4 (102) TE-631GM-1
8 (203) TE-6311M-1
TE-6311P-1
18 (457) TE-631JM-1
Flange (VAV) 4 (102) TE-631GV-2
8 (203) TE-6311V-2
Flush N/A TE-6310F-0
TE-6310F-1
Outdoor air 3 (76) TE-6313P-1
Strap-mount 3 (76) TE-631S-1
Wall 2 N/A TE-6314P-1
Well 6 (152) TE-631AM-1 3
TE-631AM-2
TE-631AP-1
8 (203) TE-6312M-1
TE-6312P-1
Platinum (1k ohm) Adjustable 8 (203) TE-6351A-1
Duct 4 (102) TE-635GM-1
8 (203) TE-6351M-1
TE-6351P-1
18 (457) TE-635JM-1
Flange (VAV) 4 (102) TE-635GV-2
8 (203) TE-6351V-2
Flush N/A TE-6350F-0
TE-6350F-1
Outdoor air 3 (76) TE-6353P-1
Strap-mount 3 (76) TE-635S-1
Wall 2 N/A TE-6324P-1
Well 6 (152) TE-635AM-1 3
TE-635AM-2
TE-635AP-1
8 (203) TE-6352M-1
TE-6352P-1
Platinum Equivalent 1k ohm Averaging 1 10 ft (3 m) TE-6327P-1
20 ft (6.1 m) TE-6328P-1
100 ohm Averaging 1 10 ft (3 m) TE-6337P-1
20 ft (6.1 m TE-6338P-1
Thermistor (2.2k ohm) Adjustable 8 (203) TE-6341A-1
Duct 8 (203) TE-6341P-1
Flange (VAV) 4 (102) TE-634GV-2
8 (203) TE-6341V-2
Outdoor Air 3 (76) TE-6343P-1
Wall 2 N/A TE-6344P-1
Well 6 (152) TE-634AM-2
8 (203) TE-6342M-1
Thermistor (10k ohm) Type II Adjustable 8 (203) TE-6361A-1
Duct 4 (102) TE-636GM-1
8 (203) TE-6361M-1
TE-6361P-1
18 (457) TE-636JM-1
Flange (VAV) 4 (102) TE-636GV-2
8 (203) TE-6361V-2
Flange (economizer) 2 (51) TE-6369E-2
6 (152) TE-636ME-2
8 (203) TE-6361E-2
12 (305) TE-636NE-2
Flush N/A TE-6360F-0
TE-6360F-1
Outdoor air 3 (76) TE-6363P-1
Strap-mount 3 (76) TE-636S-1
Well 6 (152) TE-636AM-1 3
TE-636AM-2
8 (203) TE-6362M-1
Table 2. Optional Accessories
Product Code Number Description
F-1000-182 Thermal conductive grease for element wells (8 oz. [0.23 kg])
T-4000-119 Allen head tool for wall mount cover screws (order in multiples of 30)
TE-1800-9600 Mounting hardware for mounting the wall-mount unit to a wall box
TE-6001-8 Averaging sensor mounting bracket (order in multiples of ten)
TE-6001-13 Metal cover and gasket kit (order in multiples of five)
TE-6300-101 12 in. (305 mm) 1k ohm nickel probe (cut to an appropriate length) 4
TE-6300-103 1/2-14 NPT plastic sensor holder without retainer (order in multiples of ten)
TE-6300-105 12 in. (305 mm) 1k ohm platinum Class A probe (cut to an appropriate length)5
TE-6300-601 8 in. (203 mm) 1k ohm nickel probe
TE-6300-603 3 in. (76 mm) 1k ohm nickel probe
TE-6300-605 1/2-14 NPT threaded plastic sensor holder/well adaptor with retainer (order in multiples of ten)
TE-6300-606 8 in. (203 mm) 2.2k ohm thermistor probe
TE-6300-607 3 in. (76 mm) 2.2k ohm thermistor probe
TE-6300-611 1/2-14 NPT threaded brass sensor holder/well adaptor (order in multiples of ten)
TE-6300-612 Threadless brass sensor holder/well adaptor (order in multiples of ten)
TE-6300-613 IMC kit with metal plugs and clamp connector (order in multiples of ten)
TE-6300-614 Cable tie mounting kit, 0.50 to 2.625 in. (12.7 to 66.7 mm) bundle diameter (order in multiples of ten)
TE-6300-615 Cable tie mounting kit, 11 in. (280 mm) maximum bundle diameter
TE-6300-616 8 in. (203 mm) 1k ohm platinum Class A probe
TE-6300-617 3 in. (76 mm) 1k ohm platinum Class A probe
TQ-6000-1 4 to 20 mA output transmitter for use with the 100 ohm platinum sensor
TE-6300W-101 5 Thermowell, brass with copper bulb, 2.38 in. (60.5 mm) immersion depth, with thermal grease, direct mount, no adaptor required, for use with 6 in. (150 mm) probe model TE-63xAM-2
TE-6300W-1025 Thermowell, stainless steel, 2.38 in. (60.5 mm) immersion depth, without thermal grease, direct mount, no adaptor required, for use with 6 in. (150 mm) probe model TE-63xAM-2
TE-6300W-103 Thermowell, brass with copper bulb, 2.38 in. (60.5 mm) immersion depth, with thermal grease, threadless adaptor required, for use with 6 in. (150 mm) probe models TE-63xAM-1 (adaptor included) and TE-63xAP-1 (adaptor included)
TE-6300W-110 Thermowell, stainless steel, 4.50 in. (114.3 mm) immersion depth, without thermal grease, 1/2-14 NPT adaptor required, for use with 8 in. (200 mm) probe models TE-63x2M-1 (adaptor included) and TE-63x2P-1 (adaptor included)
Table 3. T-4000 Covers Available for the Wall Mount TE-63x4P Series
Product Code Number Horizontal Johnson Controls Logo Vertical Johnson Controls Logo Thermometer,with °F/°C Scale Faceplate/Cover Color
T-4000-21386       Brushed aluminum/beige
T-4000-2139    
T-4000-2140  
T-4000-2144    
T-4000-2639     Brown and gold/beige
T-4000-2640  
T-4000-2644    
T-4000-3139     Brushed aluminum/white
T-4000-3140  
T-4000-3144    
1 Two TE-6001-8 Element Holders come with the platinum equivalent averaging sensors. Order separately to use with a nickel averaging sensor.
2 Order the TE-1800-9600 Mounting Hardware separately to mount the wall unit to a wallbox.
3 TE-631AM-1, TE-635AM-1, and TE-636AM-1 include TE-6300-612 Threadless Brass Sensor Holder/Well Adaptor for retrofit toTE-6300W-103 or WZ-1000-5 Thermowells.
4 Cut 12 in. (305 mm) probes to a minimum of 3 in. (76 mm).
5 Direct-mount thermowells TE-6300W-101 and TE-6300W-102 can be used only with the TE-6300M Sensors.
6 Without Johnson Controls logo