| Code number | Callout | Description | |||
|---|---|---|---|---|---|
|
A |
Packing kits |
Valve size, in. |
Actuator size |
Type of packing |
|
|
V-9999-613 |
2-1/2 through 4 |
(VB-4322) |
EPDM ring pack |
||
|
V-9999-613 |
2-1/2 and 3 |
5R |
EPDM ring pack |
||
|
V-5252-668 |
3 through 6 |
8R |
EPDM ring pack |
||
|
Purchase locally quantity required per valve |
B |
Lower cap screws |
Valve size, in. |
Screw size, in. |
|
|
6 |
2-1/2 |
1 x 5/16 to 18 |
|||
|
6 |
3 |
1 x 3/8 to 16 |
|||
|
8 |
4 |
1-1/4 x 3/8 to 16 |
|||
|
8 |
5 |
1-1/4 x 1/2 to 13 |
|||
|
10 |
6 |
1-1/2 x 1/2 to 13 |
|||
|
Purchase locally quantity required per valve |
C |
Upper cap screws |
Valve size, in. |
Screw size, in. |
|
|
6 |
2-1/2 |
3/4 x 5/16 to 18 |
|||
|
6 and 8 |
3 and 4 |
7/8 x 3/8 to 16 |
|||
|
8 and 10 |
5 and 6 |
1 x 1/2 to 13 |
|||
| Code number | Valve size, in. | Actuator | Reconditioning kits 1 |
|---|---|---|---|
|
V-5842 |
2-1/2 |
5R |
V-5842-6001 |
|
3 |
5R or 8R |
V-5842-6002 5R or V-5842-6003 8R |
|
|
4 |
5R or 8R |
V-5842-6004 (Elect) or V-5842-6005 8R |
|
|
5 |
8R |
V-5842-6006 |
|
|
6 |
8R |
V-5842-6007 |
WARNING
WARNING
WARNING
1 Reconditioning kit includes stem,
packing nut, follower, packing box, packing, bonnet, gasket,
swivel, pins, disc holder, screws, lower plug, upper plug, guide
rod, packing spacer, packing tools, and instructions.