The application System Selection trees use the individual modules in this group using the names in the following table.

Table 1. Equipment Interlock Uses in Application System Selection Trees

Module Instance Name

Application

2 Pipe Pump Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU Mixed Air Single Duct Applications

2 Pipe Pump X Interlock (Where X is 1–2)

AHU 100% Outdoor Air Single Duct Applications

AHU Mixed Air Single Duct Applications

Chiller X Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

CHW X IsoVlv Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

CHW Pump X Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

CW Pump X Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

Cooling Pump Interlock

All Air Handling Unit Applications

Cooling Pump X Interlock (Where X is 1–2)

All Air Handling Unit Applications

Cooling Tower X Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

CT X IsoVlv Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

CW X IsoVlv Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

EA Damper Interlock

AHU 100% Outdoor Air Single Duct Applications

EA Damper2 Interlock

AHU 100% Outdoor Air Single Duct Applications

Exhaust Fan Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

Exhaust Fan2 Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

GEF Interlock

All Air Handling Unit Applications

Heat Recovery Pump Interlock

All Air Handling Unit Applications

HR Energy Wheel Interlock

All Air Handling Unit Applications

HxX CHW IsoVlv Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

HxX CW IsoVlv Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

HxX Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

HW Pump X Interlock (Where X is 1–8)

Central Cooling Applications

Central Heating Applications

Min Outdoor Air Fan Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

OA Damper Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

OA Damper2 Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

Preheat Pump Interlock

All Air Handling Unit Applications

Preheat Pump X Interlock (Where X is 1–2)

All Air Handling Unit Applications

Reheat Pump Interlock

All Air Handling Unit Applications

Reheat Pump X Interlock (Where X is 1–2)

All Air Handling Unit Applications

Relief Fan Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

Relief Fan2 Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

Return Fan Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Return Fan2 Interlock

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Secondary Pump X Interlock (Where X Is 1–8)

Central Cooling with Optimization Applications

TEF Interlock

All Air Handling Unit Applications

Zone X Pump A Interlock (Where X is 1–8)

Central Cooling Applications

Central Heating Applications

Zone X Pump B Interlock (Where X is 1–8)

Central Cooling Applications

Central Heating Applications

To see a module's connections and how modules interact with it, view the Connections table.