Module Use in Applications (Motor Protection) - Johnson Controls - Metasys - LIT-12011147 - Software Application - Controller Configuration Tool - 16.0

Controller Tool Help

Brand
Johnson Controls
Metasys
Product name
Controller Configuration Tool
Document type
User Guide
Document number
LIT-12011147
Version
16.0
Revision date
2023-10-02
Language
English

The application System Selection trees use the individual modules in this group using the names in the following table.

Table 1. Motor Protection Uses in Application System Selection Trees

Module Instance Name

Applications

2 Pipe Pump Blocking Protection

AHU Mixed Air Single Duct Applications

AHU 100% Outdoor Air Single Duct Applications

2 Pipe Pump X Blocking Protection (Where X is 1 or 2)

AHU Mixed Air Single Duct Applications

AHU 100% Outdoor Air Single Duct Applications

Cooling Pump Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Cooling Pump X Blocking Protection (Where X is 1 or 2)

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

CWPX Blocking Protection (Where X Is 1-8)

Central Cooling Applications

Exhaust Fan Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

GEF Blocking Protection (General Exhaust Fan Blocking Protection)

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

AHU Mixed Air Single Duct Applications

Heat Pump Application

Heat Recovery Pump Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

HR Energy Wheel Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

PCHWPX Blocking Protection (Where X Is 1-8)

Central Cooling Applications

PHWPX Blocking Protection (Where X Is 1-8)

Central Heating Applications

Preheat Pump Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Preheat Pump X Blocking Protection (Where X is 1 or 2)

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Reheat Pump Blocking Protection

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

Reheat Pump X Blocking Protection (Where X is 1 or 2)

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

SCHWPX Blocking Protection (Where X Is 1-8)

Central Cooling Applications

SHWPX Blocking Protection (Where X Is 1-8)

Central Heating Applications

TEF Blocking Protection (Toilet Exhaust Fan Blocking Protection)

AHU Mixed Air Single Duct Applications

AHU Mixed Air Dual Duct Applications

AHU 100% Outdoor Air Single Duct Applications

AHU 100% Outdoor Air Dual Duct Applications

AHU Multizone (Mixed Air Dual Duct) Applications

AHU Mixed Air Single Duct Applications

Heat Pump Application

TwrFanX Blocking Protection (Where X Is 1-8)

Central Cooling Applications

To see a module's connections and how modules interact with it, view the Connections table.