Right-Click Menus (Control Tab) - Johnson Controls - Metasys - LIT-12011147 - Software Application - Controller Configuration Tool - 13.1

Controller Tool Help

Brand
Johnson Controls
Metasys
Product name
Controller Configuration Tool
Document type
User Guide
Document number
LIT-12011147
Version
13.1
Revision date
2019-12-04
Language
English

The following table lists the right-click menu options on the Control tab and indicates the mode and item in which the menu is available. Menu options appear in the right-click menu when an item is selected.

Table 1. Right-Click Menus (Control Tab)

Menu Option

Appears in Mode

Control View Section

Description

NI=Network Inputs

I=Inputs

MI=Miscellaneous Inputs

S/M=Setpoint/Miscellaneous

SG=State Generation

OC=Output Control

NO=Network Outputs

O=Outputs

MO=Miscellaneous Outputs

NI

I

MI

S/M

SG

OC

NO

O

MO

New (Header Only)

Configuration

X

X

X

X

X

X

X

X

X

Adds a new module or point.

Simulation

                 

Commissioning

                 

Delete (Delete key)

Configuration

X

X

X

X

X

X

X

X

X

Removes the module.

Simulation

                 

Commissioning

                 

Rename (F2 key)

Configuration

X

X

X

X

X

X

X

X

X

Changes the name of the module.

Simulation

                 

Commissioning

                 

View Details

Configuration

X

X

X

X

X

X

X

X

X

Details dialog box to view the details of the selected module.

Simulation

X

X

X

X

X

X

X

X

X

Commissioning

X

X

X

X

X

X

X

X

X

View FSM Explorer Configuration         X         Opens the FSM Explorer wizard. See FSM Explorer for more information.
Simulation         X        
Commissioning         X        
Insert Logic (Insert key) 1

Configuration

     

X

X

X

     

Opens the New Module Selection dialog box for the selected module. This menu option is available only when the module has logic that can be viewed or modified (indicated by a tan background).

Simulation

                 

Commissioning

                 

View Logic1

Configuration

     

X

X

X

     

Opens the Logic View for the selected module. This menu option is available only when the module has logic that can be viewed or modified (indicated by a tan background).

Simulation

     

X

X

X

     

Commissioning

     

X

X

X

     
Export Module1

Configuration

     

X

X

X

      Opens the Save Module dialog box. This menu option is available only when the module has logic that can be viewed or modified (indicated by a tan background). See Importing and Exporting a Module.

Simulation

                 

Commissioning

                 
Select Default Element1

Configuration

     

X

X

X

      Opens the Default Element Selection dialog box. This menu option is available only when the module has logic that can be viewed or modified (indicated by a tan background). See Default Element Selection.

Simulation

                 

Commissioning

                 

Commands

Configuration

                 

Opens the Commands dialog box to command items.

Simulation

X

X

X

X

X

X

X

X

X

Commissioning

X 2

X2

X2

X2

X2

X2

X2

X2

X2

Hardware Commands

Configuration

                 

Opens the Hardware Commands dialog box to issue a command to the selected item.

Simulation

                 

Commissioning

 

X

X

       

X

X

Modify Signal

Configuration

 

X

X

       

X

X

Use to change the signal type of Inputs and Outputs in Configuration mode.

Simulation

                 

Commissioning

                 

Show Involvement

Configuration

             

X

X

Opens the Show Involvement dialog box that shows connected modules in magenta highlighting.

Simulation

             

X

X

Commissioning

             

X

X

1 Only available for modules containing logic that can be viewed or modified indicated by a tan background). See the Control Tab Status Colors and Icons section.
2 Only available in Test Mode.