Changing the settings of the AirconFeedbackCommand Service - Johnson Controls - LIT-12013270 - Software Application - Companion - 1.1

Companion Installation Guide

Brand
Johnson Controls
Product name
Companion
Document type
Installation Guide
Document number
LIT-12013270
Version
1.1
Revision date
2019-10-23
Language
English

About this task

To change the settings of the AirconFeedbackCommand Service file, complete the following steps:

Procedure

  1. Navigate to the following location: C:\services\servicescompanion\JCI.MyWorkplace.Integration.AirconFeedbackCommand\.
  2. Double-click the JCI.MyWorkplace.Integration.AirconFeedbackCommand.exe.config file.
  3. Navigate to the Connection: Connection String section:
    You must make the following changes to the section:
    • Replace [SQLServerInstance] with the SQL Server Instance name.
    • Replace [DatabaseName] with the word Companion.
    • Replace [Id] with the SQL Login User ID.
    • Replace [Pwd] with the SQL Login Password.
  4. Navigate to the appSettings section:
    You must make the following changes to the section:
    • Replace the [OutlookExchangeURL] key value with the Outlook Exchange URL link.
    • Replace [OutlookAdminEmail] and [OutlookAdminPassword] with the POP3 account details.