Color Terminal Equipment Controller (TEC) Protocol Implementation Conformance Statement

Product
Document number
LIT-12013203
Revision date
2020-05-21

Dynamically Creatable: No

Dynamically Deletable: No

Table 1. Device
Property name Required Optional Proprietary Property ID Data type Writable Range
OBJECT_IDENTIFIER     75 BACnetObjectIdentifier    
OBJECT_NAME     77 CharacterString    
OBJECT_TYPE     79 BACnetObject Type    
SYSTEM_STATUS     112 DeviceStatus    
VENDOR_NAME     121 CharacterString    
VENDOR_IDENTIFIER     120 Unsigned16    
MODEL_NAME     70 CharacterString    
FIRMWARE_REVISION     44 CharacterString    
PROTOCOL_VERSION     98 Unsigned    
PROTOCOL_REVISION     139 Unsigned    
PROTOCOL_SERVICES_SUPPORTED     97 BACnetServices Supported    
PROTOCOL_OBJECT_TYPES_SUPPORTED     96 BACnetObject Types Supported    
OBJECT_LIST     76 BACnetObject Identifier    
SEGMENTATION_SUPPORTED     107 BACnet Segmentation    
DEVICE_ADDRESS_BINDING     30 BACnetLISTof BACnet Address Binding    
DATABASE_REVISION     155 Unsigned    
APDU_TIMEOUT     11 Unsigned 1 1,000–65,535 in milliseconds
MAX_APDU_LENGTH_ACCEPTED     62 Unsigned 1  
NUMBER_OF_APDU_RETRIES     73 Unsigned 1  
APPLICATION_SOFTWARE_VERSION     12 CharacterString  
ACTIVE_COV_SUBSCRIPTIONS     152 BACnetLIST of BACnetCOVSubscription    
ADPU_SEGMENT_TIMEOUT     10 Unsigned 1 1,000–65,535 in milliseconds
DAYLIGHT_SAVINGS_STATUS     24 BOOLEAN    
DESCRIPTION     28 CharacterString 40 characters max
LOCAL_DATE     56 Date    
LOCAL_TIME     57 Time    
LOCATION     58 CharacterString  
MAX_INFO_FRAMES     63 Unsigned  
MAX_MANAGER     64 Unsigned(0..127) 1–127
MAX_SEGMENTS_ACCEPTED     167 Unsigned    
UTC_OFFSET     119 INTEGER    
CONFIGURATION_FILES            
LAST_RESTORE_TIME     157 TimeStamp    
BACKUP_FAILURE_TIME          
TIME_SYNCHRONIZATION_RECIPIENTS          
TIME_SYNCHRONIZATION_INTERVAL     204 Unsigned  
UTC_TIME_SYNC_RECIPIENTS          
ALIGN_INTERVALS     193 BOOLEAN  
INTERVAL_OFFSETS          
TIME_OF_DEVICE_RESTART     203 BACnet TimeStamp    
LAST_RESTART_REASON     196 BACnetRestart Reason    
RESTART_NOTIFICATION_RECIPIENTS     202 BACnetLIST of BACnetRecipient  
ALARM_STATE     1006 Enumerated    
ARCHIVE_DATE     849 Date    
ARCHIVE_STATUS     1187 Unsigned    
ARCHIVE_TIME     850 Time    
COV_RECEIVE_RATE     650 Unsigned    
COV_TRANSMIT_RATE     651 Unsigned    
CPU_USAGE     2583 Real    
DEFAULT_BASE_UNITS     2203 Enumerated    
ENABLED     673 Boolean    
ESTIMATED_FLASH_AVAILABLE     2 2395 Real    
EXTENDED_PROTO_VERSION     2291 Unsigned    
FLASH_USAGE     2584 Real    
ITEM_REFERENCE     32527 String    
LAST_IDLE_SAMPLE     30082 Real    
MAX_MESSAGE_BUFFER     848 Unsigned  
MEMORY_USAGE     2581 Real    
OBJECT_MEMORY_USAGE     2582 Real    
STATUS     512 Enumerated    
1 Write does not take effect until after reboot.
2 Not present in all instances.