Accessories - Facility Explorer - LIT-1900766 - Field Device - FX-PCV19 Programmable VAV Box Controller - FX-PCV16 Programmable VAV Box Controller - FX-PCV18 Programmable VAV Box Controller

FX-PCV Programmable VAV Box Controllers Catalog Page

Product
Variable Air Volume > Variable Air Volume Box Controls > FX-PCV19 Programmable VAV Box Controller
Variable Air Volume > Variable Air Volume Box Controls > FX-PCV16 Programmable VAV Box Controller
Variable Air Volume > Variable Air Volume Box Controls > FX-PCV18 Programmable VAV Box Controller
Document number
LIT-1900766
Revision date
2019-08-22
Table 1. FX-PC Family accessories (order separately)
Product code number Description

FX-DIS1710-0

Local Controller Display. Text only available in English.

FX-BTCVT-1

Bluetooth® Commissioning Converter

TL-BRTRP-0

Portable BACnet/IP to MS/TP Router

FX-ATV7003-0

Handheld VAV Box Balancing Tool

FX-ZFR1810-1

Wireless Field Bus Coordinator, 10 mW Transmission Power. Functions with FX Supervisory Controllers.

FX-ZFR1811-1

Wireless Field Bus Router, 10 mW Transmission Power. Functions with FX-PC controllers and FX-WRZxxx Series Wireless Sensors

FX-ZFR1812-1

Wall-mount Wireless Field Bus Router, 10 mW Transmission Power. Functions with BACnet FX-PC controllers and FX-WRZ Series Wireless Mesh Room Sensors.

FX-ZFRCBL-0

Wire Harness which allows an FX-PCV1610/1620 to be connected to an SA Bus device (Bluetooth Commissioning Converter, Local Controller Display, or NS Series Sensor) when its SA Bus RJ-12 jack is occupied by an FX-ZFR1811 router.

FX-BTCVTCBL-700

Cable Replacement Set for the FX-BTCVT-1 or the FX-ATV7003-0; Includes One 5 ft (1.5 m) Retractable Cable

FX-WRZ Series Wireless Sensors

FX-WRZ Series Wireless Sensors: Refer to the FX-WRZ Series Wireless Room Sensors Product Bulletin (LIT-12011687) for specific sensor model descriptions.

NS Series Sensors

NS Series Network Sensors: Refer to the NS Series Network Sensors Product Bulletin (LIT-12011574) for specific sensor model descriptions.

Y64T15-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 92 VA, Foot Mount, 30 in. Primary Leads and 30 in. Secondary Leads, Class 2

Y65A13-0

Transformer, 120 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AS), 8 in. Primary Leads and 30 in. Secondary Leads, Class 2

Y65T42-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Hub Mount (Y65SP+), 8 in. Primary Leads and Secondary Screw Terminals, Class 2

Y65T31-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AR+), 8 in. Primary Leads and Secondary Screw Terminals, Class 2

AP-TBK1002-0

2-Position Screw Terminal that Plugs onto FX-PCV Output Point Spade Lug

AP-TBK1003-0

3-Position Screw Terminal that Plugs onto FX-PCV Output Point Spade Lugs

AP-TBK4SA-0

Replacement MS/TP SA Bus Terminal, 4-Position Connector, Brown (Bulk Pack of 10)

AP-TBK4FC-0

Replacement MS/TP FC Bus Terminal, 4-Position Connector, Blue (Bulk Pack of 10)

AP-TBK3PW-0

Replacement Power Terminal, 3-Position Connector, Gray (Bulk Pack of 10)

AS-CBLVMA-1

Cable Adapter, 8-Pin Female Socket to 6-Pin Male Jack (Bulk Pack of 10)

AS-CBLVMA-2

Cable Adapter, 8-Pin Female Socket to 8-Pin Male Jack with 6-Pin Female Socket for Wireless Commissioning Converter (Bulk Pack of 10)

MS-TBKLV03-0

Terminal Block Kit - FX-PCA Line Voltage AC Power - 3 Pieces

MS-TBKRO02-0

Terminal Block Kit -FX-PCA 2-Position Relay Output - 9 Pieces

MS-TBKRO03-0

Terminal Block Kit - FX-PCA 3-Position Relay Output - 6 Pieces

MS-TBKCO04-0

Terminal Block Kit - FX-PCA 4-Position Configurable Output - 6 Pieces

MS-TBKUI04-0

Terminal Block Kit - FX-PCA 4-Position Universal Input - 3 Pieces

MS-TBKUI05-0

Terminal Block Kit - FX-PCA 5-Position Universal Input - 3 Pieces

FX-PCVACT-701

Actuator Assembly Gearbox Replacement Kit for FX-PCV1615-0, FX-PCV1617-0, FX-PCV1630-0, FX-PCV1632-0, and FX-PCV1832-0

NS-WALLPLATE-0

Network Sensor Wall Plate

TE730-29C-0

Platinum 1k ohm Thin Film Resistive Temperature Sensor

TE730-39C-0

Platinum 1k ohm Thin Film Resistive Temperature Sensor with Integral Manual Occupancy Override Push Button

FX-WRZ7860-0

One-to-One ZigBee Wireless Receiver for Wireless Sensor Only Applications

FX-WRZSST-120

Wireless Sensing System Tool Kit

ZFR-USBHA

USB Dongle with ZigBee® Driver provides a wireless connection through CCT to allow wireless commissioning of the wirelessly enabled FX-PCA, FX-PCG, FX-PCV, and FX-PCX programmable controllers. Also allows use of the FX-ZFR Checkout Tool (FX-ZCT) in CCT.

Note: The ZFR-USBHA-0 replaces the IA OEM DAUBI_2400 ZigBee USB dongle. For additional information on the ZFR-USBHA-0 ZigBee dongle, refer to the FX-ZFR Series Wireless Field Bus System Technical Bulletin (LIT-12011660) or FX-ZFR Series Wireless Field Bus System Quick Reference Guide (LIT-12011696).