FX-PC Family accessories ordering Information - Facility Explorer - LIT-12011657 - Accessory - Field Device - BTCVT Wireless Commissioning Converter - FX-PCA26 Advanced Application Programmable Controller - FX-PCA36 Advanced Application Programmable Controller - FX-PCA49 Advanced Application Programmable Controller - FX-PCG16 General Purpose Programmable Controller - FX-PCG26 General Purpose Programmable Controller - FX-PCV16 Programmable VAV Box Controller - FX-PCV18 Programmable VAV Box Controller - FX-PCV19 Programmable VAV Box Controller - FX-PCX17 Expansion Input/Output Module - FX-PCX27 Expansion Input/Output Module - FX-PCX37 Expansion Input/Output Module - FX-PCX47 Expansion Input/Output Module - Handheld VAV Balancing Sensor/Tool

FX-PC Series Programmable Controllers and Related Products Product Bulletin

Brand
Facility Explorer
Product name
BTCVT Wireless Commissioning Converter
FX-PCA26 Advanced Application Programmable Controller
FX-PCA36 Advanced Application Programmable Controller
FX-PCA49 Advanced Application Programmable Controller
FX-PCG16 General Purpose Programmable Controller
FX-PCG26 General Purpose Programmable Controller
FX-PCV16 Programmable VAV Box Controller
FX-PCV18 Programmable VAV Box Controller
FX-PCV19 Programmable VAV Box Controller
FX-PCX17 Expansion Input/Output Module
FX-PCX27 Expansion Input/Output Module
FX-PCX37 Expansion Input/Output Module
FX-PCX47 Expansion Input/Output Module
Handheld VAV Balancing Sensor/Tool
Document type
Product Bulletin
Document number
LIT-12011657
Revision date
2019-12-06
Table 1. FX-PC Family Accessories (Order Separately)
Product Code Number Description

FX-DIS1710-0

Local Controller Display: Refer to FX-DIS Local Controller Display Product Bulletin (LIT-12011667) for more information.

FX-BTCVT-1

Bluetooth Commissioning Converter with Bluetooth Technology

NS-ATV7003-0

Handheld VAV Balancing Tool

FX-ZFR1810-1

Wireless Field Bus Coordinator for use in the FX-ZFR1800 Wireless Field Bus System. For more information, refer to the FX-ZFR Series Wireless Field Bus System Product Bulletin (LIT-12011686).

FX-ZFR1811-1

Wireless Field Bus Router for use in ZFR1800 Wireless Field Bus System. For more information, refer to the FX-ZFR Series Wireless Field Bus System Product Bulletin (LIT-12011686).

FX-ZFR1812-1

Wall Mount Wireless Field Bus Router for use in ZFR1800 Wireless Field Bus System. For more information, refer to the FX-ZFR Series Wireless Field Bus System Product Bulletin (LIT-12011686).

FX-WNC1800-xx

Wireless Network Coordinator (WNC) Gateway for use in FX-ZFR Pro Series Wireless Field Bus system.

FX-ZFR1821-x and FX-ZFR1822-x

FX-ZFR1821 or FX-ZFR1822 Pro Wireless Router/Repeater for use in FX-ZFR Pro Series Wireless Field Bus system. For more information refer to the WNC1800/FX-ZFR182x Pro Series Wireless Field Bus System Product Bulletin (LIT-12012378).

FX-ZFR1820 and FX-ZFR1823

FX-ZFR1820 FX-ZFR1823 Pro Coordinator Radio for use in FX-ZFR Pro Series Wireless Field Bus system. For more information refer to the WNC1800/FX-ZFR182x Pro Series Wireless Field Bus System Product Bulletin (LIT-12012378).

FX-ZFRCBL-0

Wire Harness for use with FX-ZFR or FX-ZFR Pro Router. Allows any router to function with FX-PCG16 Series, FX-PCV16 Series, FX-PCA26 Series, and FX-PCG26 Series Controllers in Conjunction with NS Series Sensors, Bluetooth Commissioning Converter, or FX-DIS1710 Local Controller Display

FX-BTCVTCBL-700

Cable Replacement Set for the FX-BTCVT-1 or the FX-ATV7003-0; Includes One 1.5 m (5 ft) Retractable Cable

FX-WRZ Series Wireless Sensors

FX-WRZ Series Wireless Sensors: Refer to the FX-WRZ Series Wireless Room Sensors Product Bulletin (LIT-12011687) for specific sensor model descriptions.

NS Series Sensors

NS Series Network Sensors: Refer to the NS Series Network Sensors Product Bulletin (LIT-12011574) for specific sensor model descriptions.

Y64T15-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 92 VA, Foot Mount, 76 cm (30 in.) Primary Leads and 76 cm (30 in.) Secondary Leads, Class 2

Y65A13-0

Transformer, 120 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AS), 20 cm (8 in.) Primary Leads and 76 cm (30 in.) Secondary Leads, Class 2

8 in. (20 cm)

Y65T42-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Hub Mount (Y65SP+), 20 cm (8 in.) Primary Leads and Secondary Screw Terminals, Class 2

Y65T31-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AR+), 20 cm (8 in.) Primary Leads and Secondary Screw Terminals, Class 2

AP-TBK4SA-0

Replacement MS/TP SA Bus Terminal, 4-Position Connector, Brown (Bulk Pack of 10)

AP-TBK4FC-0

Replacement MS/TP FC Bus Terminal, 4-Position Connector, Blue (Bulk Pack of 10)

AP-TBK3PW-0

Replacement Power Terminal, 3-Position Connector, Gray (Bulk Pack of 10)

AS-CBLVMA-1

Cable Adapter, 8-Pin Female Socket to 6-Pin Male Jack (Bulk Pack of 10)

AS-CBLVMA-2

Cable Adapter, 8-Pin Female Socket to 8-Pin Male Jack with 6-Pin Female Socket for Wireless Commissioning Converter (Bulk Pack of 10)

MS-TBKLV03-0

Terminal Block Kit - FX-PCA Line Voltage AC Power - 3 Pieces

MS-TBKRO02-0

Terminal Block Kit - FX-PCA 2-Position Relay Output - 9 Pieces

MS-TBKRO03-0

Terminal Block Kit - FX-PCA 3-Position Relay Output - 6 Pieces

MS-TBKCO04-0

Terminal Block Kit - FX-PCA 4-Position Configurable Output - 6 Pieces

MS-TBKUI04-0

Terminal Block Kit - FX-PCA 4-Position Universal Input - 3 Pieces

MS-TBKUI05-0

Terminal Block Kit - FX-PCA 5-Position Universal Input - 3 Pieces

FX-PCVACT-701

Actuator Assembly Gearbox Replacement Kit for FX-PCV1615-0, FX-PCV1617-0, FX-PCV1630-0, FX-PCV1632-0, and FX-PCV1832-0

NS-WALLPLATE-0

Network Sensor Wallplate

TE730-29C-0

Platinum 1k ohm Thin Film Resistive Temperature Sensor

TE730-39C-0

Platinum 1k ohm Thin Film Resistive Temperature Sensor with Integral Manual Occupancy Override Pushbutton

FX-WRZ7860-0

One-to-One ZigBee Wireless Receiver for Wireless Sensor Only Applications

FX-WRZSST-120

Wireless Sensing System Tool Kit

ZFR-USBHA

USB Dongle with ZigBee® Driver provides a wireless connection through CCT to allow wireless commissioning of the wirelessly enabled FX-PCA, FX-PCG, FX-PCV, and FX-PCX programmable controllers. Also allows use of the FX-ZFR Checkout Tool (FX-ZCT) in CCT.

Note: The ZFR-USBHA-0 replaces the IA OEM DAUBI_2400 ZigBee USB dongle. For additional information on the ZFR-USBHA-0 ZigBee dongle, refer to the FX-ZFR Series Wireless Field Bus System Technical Bulletin (LIT-12011660) or FX-ZFR Series Wireless Field Bus System Quick Reference Guide (LIT-12011696).