Creating a Custom Filter within the Audit Viewer (BCPro Workstation Only) - BCPro - LIT-12011905 - Server - BCPro Data Server - 4.0
BCPro Data Server
Product
Building Automation Systems > Databases and Data Servers > BCPro Data Server
Document number
LIT-12011905
Version
4.0
Revision date
2020-03-27
Welcome
Getting Started
Related Documentation
System Overview
Printing Specific Help Topics
Printing the Help
Printing the Entire Help System
BCPro Data Server User Interface
BCPro Data Server Interface Concepts
Launcher
Login
BCPro Data Server Modes
Online Mode
Offline Mode
Access Types
Standard Access
Basic Access
Screen Layout and Frames
Navigation Tree
Items
Status Symbol
Unlicensed Items Trees
Display Frame
Display Frame Layout
Display Panel Tabs
Display Panel Buttons
Status Bar Icon
User Interface Diagnostics Window
Viewing Item Data
Operator Override Report
Commands
Pop-up Menus
Timed Inactivity Logout
BCPro Data Server Interface Steps
Changing the Display Panel Layout
Running Operator Override Report
Printing
Working With Items
Navigating to an Item
Displaying Information About an Item
Editing Items
Commanding Item
Deleting Objects/Items
Logging Out
Exiting
Menus
Menus Concepts
BCPro Modes
Authorized Menu Items
Item Menu
Close Archive
Edit Menu
Copy
Paste
Delete Items
View Menu
Extended Labels
Product Version Labels
Action Menu
Rename
Refresh
Refresh Current Tab
Refresh All Tabs
Import Integration
Remove From Site
Site Discovery
Action Menu - Item Specific
Action Menu - Feature Specific
Insert Menu
Tools Menu
User Profile
Change Password
Administrator
All Items Organizer
Select Ethernet Adapter
Create Backup
Re-Index
Archive Report
Upgrade Log
Query Menu
Help Menu
BCPro Data Server Help
About BCPro Data Server
Right-Click Menus
Right-Click Menus - Item Specific
Right-Click Menus - Feature Specific
Right-Click Menus and Menu Bar Equivalents
Wizards
Wizards Concepts
Types of Wizards
Wizard Navigation Buttons
Wizard Steps
Creating Items with Wizards
Using Wizards
New Archive Wizard
Open Archive Wizard
Copy Archive Wizard
Delete Archive Wizard
Export Archive Wizard
Import Wizard
Extension Wizard
Insert Site Wizard
Insert Device Wizard
Insert BCPro Server Wizard
Insert Integration Wizard
Insert Field Device Wizard
Insert Point Wizard
Insert Folder Wizard
Insert Object Wizard
Restore Archive Wizard
Manage Archive Wizard
Passthru Wizard
Security Copy Wizard
Paste Item Wizard
Extensions
Resource File Extensions
Resource File Attributes
Resource File Extension Attribute Details
Date
File Name
File Name: Exportable
File Name: Object Reference
File Name: References
File Name: Relative Path
File Size
Information
Time
Trend Extensions
Trend Extensions Concepts
Views
Trend Extensions Chart View
Chart Right-Click Menu
Trend Extension Table View
Trend Extension Definition View
Trend Buffer
Trend Sampling
Trend Extension Attributes
Acked Transitions
Buffer Size
Buffer State
Client COV Increment
COV Resubsc Interval
Enable
Event Enable
Event State
Event Time Stamps
Input Reference
Intrinsic Alarming Defined
Last Notify Record
Logging Type
Log Interval
Notification Class
Notification Object Reference
Notify Threshold
Notify Type
Record Count
Record Since Notify
Repository Enabled
Sample Interval
Sample Not Sent to ADS
Start Time
Status Flags
Stop Time
Stop When Full
Total Record Count
Transfer Setpoint
Trigger
Trend Extension Commands
Clear
Disable
Enable
Execute
Route
Extension Steps
Creating Extensions
Viewing Extensions
Editing Extensions
Copying and Pasting Extensions
Deleting Extensions
Searching for Extensions
Commanding Extensions
Single Extension
Multiple Extension
Interlocking a Trend Extension
Global Search
Global Search Concepts
Global Search Overview
Global Search Viewer Screen
Global Search Steps
Performing a Global Search
Stopping a Search
Working with Search Results
Selecting Objects in the Search Results
Removing Objects from the Search Results
Clearing All Search Results
Manually Adding Objects to Existing Search Results
Adding New Search Results to Existing Search Results
Sorting Search Results
Expanding and Collapsing the Global Search Viewer Display Areas
Reordering Columns in the Search Results Table
Printing the Search Results Table
Modifying Objects in the Search Results Table
Copying Search Results to the Clipboard
Commands Dialog
Commands Dialog Concepts
Commands Overview
Commands Dialog Box
Commands Dialog Steps
Commanding an Item
Modify Dialog
Single and Global Item Modify Concepts
Modify Dialog Box
Global Modify Dialog Box
Modify Attributes
Modify Dialog Steps
Modifying a Single Item
Performing a Global Modify
Using Global Modify with Global Search
Audit Trail
Audit Trail Concepts
Audit Trail Overview
Audited Events
Audit Repositories
Default Destination and Message Forwarding
Audit Message and Audit Viewer
Audit Trail Steps
Launching the Audit Viewer
Sorting the Audit Message List
Creating a Custom Filter within the Audit Viewer (BCPro Workstation Only)
Clearing the Audit Repository
Discarding Audit Messages
Forwarding Audit Messages to the Default Destination
Launching the Focus View of the Item That Generated the Audit Message
Scheduling
Scheduling Concepts
Calendar
Schedule
Today's Schedule
Weekly Schedule
Exception Schedule
Events
Scheduled Items
Dates - Calendar Entry and Exception Schedule
BACnet Clarification for Date Entries
Date/Date Range
Week and Day
Wildcards
Wildcards - Date
Wildcard-Date Range
Wildcards - Week and Day
Effective Period
Trend Scheduling
Fast Clock
Data Consistency Checking
Global Calendar
Scheduling Steps
Creating a Schedule or Calendar
Displaying an Existing Schedule or Calendar
Displaying Scheduled Events
Adding Weekly Scheduled Events
Editing Scheduled Events
Deleting Scheduled Events
Adding Exception Schedules
Editing Exception Schedules
Removing Exception Scheduling
Adding Scheduled Items
Editing Scheduled Items
Removing Scheduled Items
Editing the Effective Period of a Schedule
Creating a New Calendar Entry
Editing a Calendar Entry
Deleting a Calendar Entry
Toggling Between Calendar Views
Editing the Attributes of a Schedule or Calendar
Copying and Pasting a Schedule or Calendar (Offline Mode Only)
Deleting a Schedule or Calendar
Scheduling a Trend Extension
Scheduling the Enabled Audit Level
Copying Events within the Weekly Schedule
Security Copy
Security Copy Concepts
Security Copy Restore
Security Copy Considerations
Security Copy Steps
Restoring Security Databases
Database Uploading, Downloading, Upgrading Device and Synchronization
Database Uploading, Downloading, Upgrading Device and Synchronization Concepts
Upload
Download
Synchronize
Database Locking
Upgrading Device
Database Uploading, Downloading, Upgrading Device and Synchronization Steps
Uploading, Downloading, Upgrading Device or Synchronizing a Database
ActionQ
ActionQ Concepts
ActionQ Operation
ActionQ Interface
ActionQ Steps
Launching the ActionQ
Enabling/Disabling a Command
Rescheduling a Command
Viewing the Status of a Command
Deleting a Command
Automatically Deleting Completed Commands
Diagnostics
Diagnostics Steps
Displaying Diagnostic Data
Object Help
Object Help Concepts
Objects
Object Extensions
Attributes
Attribute Name
Data Type
Notes
BACnet Notes
Initial Value
Values/Options/Range
Status and Display Attribute Location
Object Naming Attributes
Commands
State, Mode, and Type Sets
Common Object Attributes
Object List
Object Creation
Object Deletion
Common Object Attributes
Common Attributes
Common Object Attribute Details
Archive Date
Alarm State
Description
Enabled
Item Reference
Name
Object Category
Object Count
Object Identifier
Object Name
Object Type
Status
Version
Analog Input Object
Analog Input Attributes
Analog Input Attribute Details
COV Increment
Device Type
Display Precision
Max Value
Min Value
Present Value
Reliability
Resolution
Status Flags
Units
Update Interval
Use COV Min Send Time
Analog Output Object
Analog Output Attributes
Analog Output Attribute Details
COV Increment
Device Type
Display Precision
Max Value
Min Value
Out of Service
Present Value
Priority Array
Reliability
Resolution
Status Flag
Units
Use COV Min Send Time
Analog Output Commands
Analog Output Command Details
Operator Override
Release Operator Override
Analog Value Object
Analog Value Attributes
Analog Value Attribute Details
COV Increment
Display Precision
Max Value
Min Value
Out of Service
Present Value
Priority Array
Reliability
Status Flags
Units
Use COV Min Send Time
Analog Value Commands
Analog Value Command Details
Operator Override
Release Operator Override
BACnet Device Object
BACnet Device Attributes
BACnet Device Attribute Details
Align Intervals
APDU Retries
APDU Segment Timeout
APDU Timeout
Active COV Subscriptions
Active VT Sessions
Appl SW Version
Backup Fail Timeout
Configuration Files
DST Status
Database Revision
Description
Device Addr Binding
Firmware Version
Graphic
Graphic Alias
Interval Offset
Last Restore Time
List of Session Keys
Local Date
Local Time
Location
Max APDU Length
Max Info Frames
Max Master
Max Segments Accepted
Model Name
Offline
Profile Name
Protocol Obj Support
Protocol Revision
Protocol Ser Support
Protocol Version
Restart Notification Recipients
Segmentation
System Status
Time Synchronization Interval
Time Sync Recipients
UTC Offset
VT Classes Supported
Vendor ID
Vendor Name
BACnet Integration Object
BACnet Integration Attributes
BACnet Integration Attribute Details
Count
Device Discovery Range
Duplicate Device Identifiers
Execution Time
Periodic Update
Poll Delay
Polled Object Count
Preserve Discovered Devices
Requested Vendor ID
BACnet Protocol Engine Object
BACnet Protocol Engine Attributes
BACnet Protocol Engine Attribute Details
Abort Rcv
Abort Tx
Ack Rcv
Ack Tx
Allocated Record Count
Clear Statistics
Conf Req Rcv
Conf Req Tx
Error Rcv
Error Tx
Latch Statistics
Local Abort Tx
Net Messages Rcv
Net Message Tx
Net Rejects Rcv
Net Routed Messages
Net Routes Busy
Net Unknown Msg Rcv
Net Unknown Routes
Peak Pending Queue Count
Peak Unknown Queue Count
Pending Queue Count
Rcv Messages Discarded
Rcv Msg Rate
Rcv Record Count
Record Count
Reject Rcv
Reject Tx
Req Retries Tx
Reset Date
Reset Time
Seg Ack Rcv
Seg Ack Tx
Seg Conf Req Rcv
Seg Conf Req Tx
Seg Retries Tx
Segment Ack Rcv
Segment Ack Tx
Segment Rcv
Segment Tx
Simple Ack Rcv
Simple Ack Tx
Transaction Timeouts
Transmits Per Minutes
Tx Messages Discarded
Tx Record Count
Unconfirmed Rcv
Unconfirmed Tx
Unknown Queue Count
BACnet Protocol Engine Commands
BACnet Protocol Engine Command Details
Clear Statistics
Latch Statistics
Binary Input Object
Binary Input Concepts
BACnet Polarity Relationships
Binary Input Attributes
Binary Input Attribute Details
Active Text
Active Time Reset
COS Count
COS Time
Device Type
Elapsed Active time
Inactive Text
Out of Service
Polarity
Present Value
Reliability
State Count Reset
States Text
Status Flags
Binary Output Object
Binary Output Concepts
BACnet Polarity Relationships
Binary Output Attributes
Binary Output Attribute Details
Active Text
Active Time Reset
COS Count
COS Time
Device Type
Elapsed Active Time
Heavy Equip Delay
HED Controller
Inactive Text
Min Off Time
Min On Time
Out of Service
Polarity
Present Value
Priority Array
Reliability
State Count Reset
States Text
Status Flag
Binary Output Commands
Binary Output Command Details
Operator Override
Release Operator Override
Binary Value Object
Binary Value Attributes
Binary Value Attribute Details
Active Text
Active Time Reset
COS Count
COS Time
Elapsed Active Time
Inactive Text
Min Off Time
Min On Time
Out of Service
Present Value
Priority Array
Reliability
State Count Reset
States Text
Status Flags
Binary Value Commands
Binary Value Command Details
Operator Override
Release Operator Override
Calendar Object
Calendar Attributes
Calendar Attribute Details
Date List (Entry Detail)
Global Calendar Object Reference
Global Calendar Update
Present Value
Ethernet IP Datalink Object
Ethernet IP Datalink Attributes
Ethernet IP Datalink Attribute Details
Address Length
APDU Retries
APDU Segment Timeout
APDU Timeout
BACnet IP Port
Broadcast Address
Broadcast Receives
Broadcast Transmit
Device Address
Discarded Frames
Max APDU Length
Message Recieves
Message Transmits
Network Address
Reset Date
Reset Time
Retry Attempts
Transmit Failures
Ethernet IP Datalink Commands
Ethernet IP Datalink Command Details
Clear Statistics
Latch Statistics
Folder
Gateway Device Object
Gateway Concepts
Operating System
Software
Database
Archive
Gateway Attributes
Gateway Attribute Details
APDU Retries
APDU Segment Timeout
APDU Timeout
Archive Date
Battery Charging
Battery Condition
BIOS Version
Board Temperature
CPU Usage
Computer Name
DHCP Enabled
DNS Server IP Addresses
Domain Name
Ethernet MAC Address
Firmware Version
IP Address
IP Mask
IP Router Address
Local Date
Local Time
Memory Usage
Model Name
Obtain DNS Address Automatically
Power Consecutive Samples
Power Sampling Interval
Version
Gateway Commands
Gateway Device Command Details
Archive
Change Audit Enabled Class Level
Rediscover Text Strings
Global Data Sharing Object
Global Data Sharing Attributes
Global Data Sharing Attribute Details
Alternate Master
Execution Priority
Fail Soft
Master
Present Value
Priority for Writing
Refresh Timer
Reliability
Setup
Subordinate List
Global Data Sharing Commands
Global Data Sharing Command Details
Disable
Enable
Interlock Object
Interlock Configuration
Interlock Attributes
Interlock Attribute Details
Action Tbl 1 (True)
Action Tbl 2 (False)
Commands Priority
Executing
Execution Priority
Last Executed Date
Last Executed Time
Logic
Logic Equations
Present Value
Priority Array
Reliability
Restore Command Priority
Send OK
Source
States Text
Interlock Commands
Interlock Command Details
Disable
Enable
Operator Override
Release Operator Override
Re-Command
MS/TP Field Bus Integration Object
MS/TP Field Bus Integration Attributes
MS/TP Field Bus Integration Attribute Details
APDU Retries
APDU Timeout
APDU Segment Timeout
Active Baud Rate
Baud Rate Selection
Broadcast Receive Rate
Broadcast Receives
Broadcast Transmits
Broadcast Transmit Rate
Buffer Overflows
Bus Analysis Date
Bus Analysis Time
Bus Analysis Progress
Bus Device Configuration List
Bus Health Index
Bus Performance Index
Bytes In
Bytes Out
Count
Data CRC Errors
Data Expecting Reply Frames Rxed
Data Expecting Reply Frames Txed
Data Not Expecting Reply Frames Rxed
Data Not Expecting Reply Frames Txed
Device Discovery Range
Discover All As General BACnet Device
Duplicate Device Identifiers
Execution Priority
Execution Time
Framing Errors
Header CRC Errors
Internal Errors
Internode Comm Timer
Lost Token
Max APDU Length
Max Master
Max Output Queue Used
Maximum Token Loop Time
Overrun Errors
PFM Frames Rxed
PFM Frames Txed
Packets Timed Out
Packets Too Long
Page Size
Periodic Update
Poll Delay
Polled Object Count
Port Status
Predicted Token Loop Time
Preserve Discovered Devices
Reply Postponed Frames Rxed
Reply Postponed Frames Txed
Reply Too Slow Application Errors
Reply Too Slow Datalink Errors
Requested Vendor ID
Reset Date
Reset Time
Retries
Synchronize Time
Synchronize Time Zone
Test Request Frames Rxed
Test Request Frames Txed
Token Frames Rxed
Token Frames Txed
Token Loop Time
Unexpected Frames Rxed
Weighted Bus Health Constant
Weighted Bus Performance Constant
MS/TP Field Bus Integration Commands
MS/TP Field Bus Integration Command Details
Analyze Field Bus
Clear Statistics
Latch Statistics
Multiple Command Object
Multiple Command Attributes
Multiple Command Attribute Details
Action Table (State0. . . StateN)
Command Priority
Enabled
Executing
Execution Priority
Last Executed Date
Last Executed Time
Number of States
Present Value
Relinquish Default
Send OK
States Text
Multiple Command Commands
Multiple Command Object Command Details
Disable
Enable
Operator Override
Release Operator Override
Multistate Input Object
Multistate Input Attributes
Multistate Input Attribute Details
Device Type
Number of States
Out of Service
Present Value
Reliability
State Text
States Text
Status Flags
Multistate Output Object
Multistate Output Attributes
Multistate Output Attribute Details
Device Type
Heavy Equipment Delay
HED Controller
Number of States
Out of Service
Present Value
Priority Array
Reliability
State Text
States Text
Status Flags
Multistate Output Commands
Multistate Output Command Details
Operator Override
Release Operator Override
Multistate Value Object
Multistate Value Attributes
Multistate Value Attribute Details
Number of States
Out of Service
Present Value
Priority Array
Reliability
State Text
States Text
Status Flags
Multistate Value Commands
Multistate Value Command Details
Operator Override
Release Operator Override
Router Device Object
Router Concepts
Operating System
Software
Database
Archive
Router Attributes
Router Attribute Details
Active Baud Rate
APDU Retries
APDU Segment Timeout
APDU Timeout
Archive Date
BACnet Integrated Objects
BACnet IP Port
BACnet Routed Messages Rate
Battery Charging
Battery Condition
Baud Rate Selection
BIOS Version
Board Temperature
CPU Usage
Computer Name
DHCP Enabled
Device Object Identifier
DNS Server IP Addresses
Domain Name
Ethernet MAC Address
Firmware Version
IP Address
IP Mask
IP Router Address
Local Date
Local Time
MAC Address
Max Info Frames
Max Master
Max Segments Accepted
Memory Usage
Model Name
Network Address
Object Identifier
Obtain DNS Address Automatically
Power Consecutive Samples
Power Sampling Interval
Remote Network Address
Routing Mode
Segmentation
Token Loop Time
Router Commands
Router Device Command Details
Archive
Reset Device
Schedule Object
Schedule Object Attributes
Schedule Object Features
Display Frame Attributes
Label
Value
Status
Schedule Object Schedule Tab
Operation and Display Attributes
Effective Period
Schedule Output Type
Default Schedule Command
States Text
Display Units
Display Mode
Today's Schedule
Weekly Schedule
Exception Schedule
Scheduled Items
Schedule Object Focus/Configuration Tab
Object Attributes
Name
Description
Object Type
Object Category
Status Attributes
Enabled
Status Flags
Reliability
Out of Service
Error Status
Alarm State
Engineering Value Attributes
Item Reference
Version
Execution Attributes
Execution Priority
Priority for Writing
Scheduled Commands
Disable
Enable
Signal Select Object
Signal Select Concepts
Average Output Computation
Logical OR Computation
Logical AND Computation
Signal Select Attributes
Signal Select Attribute Details
Average Output
Execution Priority
Failsoft
High OR
Input List
Low AND
Point Type
Present Value
Reliability
Setup
Signal Select Commands
Signal Select Command Details
Disable
Enable
Site Object
Site Attributes
Site Attribute Details
All Items Update in Progress
Device Time Servers
Poll Rate
Site Director
Site Time Servers
Time Sync Period
Time Zone
Site Commands
Site Command Details
Update Broadcast Management
Global Time Broadcast
Workstation Device Object
Workstation Concepts
Operating System
Software
Database
Archive
Workstation Attributes
Workstation Attribute Details
APDU Retries
APDU Segment Timeout
APDU Timeout
Archive Date
Average Intermittent Failure Period
BACnet Broadcast Receive Rate
BACnet Integrated Objects
BACnet IP Port
BACnet Routed Messages Rate
COV Rcv Rate
COV Tx Rate
DHCP Enabled
Detection Interval
Device Object Identifier
Duplicate References
Enabled Audit Level
Ethernet MAC Address
Firmware Version
Host Name
Internode Comm Timer
IP Address
Local Date
Local Time
Max APDU Length
Max Message Buffer
Maximum Intermittent Failure Period
Model Name
Network Address
Network Tolerance
Object Count
Object Memory Usage
Transport Failure Rate
Unbound References
Workstation Commands
Workstation Device Command Details
Archive
Change Audit Enabled Class Level
Rediscover Text Strings
Object and Feature Tabs
Action Tables Tab
Calendar Tab
Configuration Tab
Diagnostic Tab
Engineering Tab
Focus Tab
Group Tab
Hardware Tab
BACnet Hardware Tab
BACnet Hardware Tab Attribute Details
Disable Automatic Alarming
Instance Number
Remote Device Addr
Remote Object Name
MS/TP Hardware Tab
MS/TP Hardware Tab Attribute Details
Baud Rate Selection
Device Type
Disable Automatic Alarming
FC Bus MAC Address
Instance Number
MAC Address
Network Address
Offline
Trunk Number
SA Bus MAC Address
Slot
Slot A
Slot B
VND Hardware Tab
VND Hardware Tab Attribute Details
Disable Automatic Alarming
Field View
Interface Value
Max Value
Min Value
Offline
Overridden
Priority
Protocol Descriptions
Protocol Revision
Protocol Revision Date
Protocol Revision Time
Temporary Status Item Expiration Time
Trouble
Vendor Configuration Data
Vendor DLL
Vendor Integration Size
Vendor Reference
Vendor Revision Data
Vendor Revision Time
Interlock Definition Tab
Network Tab
Options Tab
Options Tab Attribute Details
Auto Restore
Ignore Relinquish Default
Local Control
Relinquish Default
Restore Command Priority
Resource Tab
Schedule Tab
Site View Tab
Summary Tab
Trend Tab
Troubleshooting
Procedure
Launch the Audit Viewer .
Click the Custom Filter radio button.
Click the Add button.
Select the criteria and the associated values for the filter and click
OK . All criteria added to the custom filter table make up the
rules of the filter.
Click Apply to get the results of the custom filter.
To view the data without the custom filter, click the Standard
Filter radio button.